SET-UP PARAMETERS
PREF
6511/6901
Display
Default
Brief Description
V/Hz
SV
CLV
4-Q PMAC
27.08
MOTOR
CONNECTION
product code
dependent
0 : DELTA
1 : STAR
Enter the type of motor
connection
x
x
71.01
PULSE ENC
VOLTS
product code
dependent
Set between 10-20V to
match the encoder
supply voltage
x
71.02
ENCODER
LINES
product code
dependent
Set to the number of
lines used by the
encoder
x
71.03
ENCODER
INVERT
0 : FALSE
1 : TRUE
Rotating Autotune sets
actual value
Encoder direction :-
when TRUE, changes
the sign of the
measured speed and
the direction of the
position count.
x
80.01
AUTOTUNE
ENABLE
0 : FALSE
1 : TRUE
Set TRUE to enable
Autotune. Resets to
FALSE when complete.
x