D-52
Programming
890CS Common Bus Supply - Frames B & D; 890CD Common Bus Drive and 890SD Standalone Drive - Frames E & F
Parameter Descriptions
STATUS
PREF: 119.13
Default: 7
Range: See below
This diagnostic shows operating and error states
Enumerated Value
:
Status
0 : READY
the Firewire Ref is operating normally
1 : REF RESET
the FireWire Ref RESET is set TRUE
2 : MASTER RESET
the Virtual Master is in Reset
3 : LOST SYNC
time stamp difference to large
4 : DUP MASTER
more than one Virtual Master with the same channel
5 : MISSING MASTER
no Virtual Master with selected channel
6 : NO FIREWIRE
no FireWire - either not fitted or no PHY power
7 : DISABLED
the FireWire CHANNEL is set to 0