Programming
D-243
890CS Common Bus Supply - Frames B & D; 890CD Common Bus Drive and 890SD Standalone Drive - Frames E & F
PREF Name
Block
Type
Range
Default
ro\rw Notes
121.16 MODE
POSITION LOOP
ENUM
0 : DISABLED
1 : ENABLED
2 : UNSYNCHRONISED
3 : SYNCHRONISED
4 : ABSOLUTE
DISABLED
ro
Output
122.01 FRICTN AT 0 RPM
INERTIA COMP
REAL
0.00 to 100.00 %
0.00 %
rw
122.02 FRN AT NMPLT
RPM
INERTIA COMP
REAL
0.00 to 100.00 %
0.00 %
rw
122.03 RELATIVE INERTIA INERTIA COMP
REAL
0.0000 to 30000.0000 % 0.0000 %
rw
122.04 FRICTION COMP
INERTIA COMP
REAL
_.xx
0.00 %
ro
Output
122.05 INERTIA COMP
INERTIA COMP
REAL
_.xx
0.00 %
ro
Output
122.06 TORQ
FEEDFORWARD
INERTIA COMP
REAL
_.xx
0.00 %
ro
Output
122.07 SPEED PI OUTPUT INERTIA COMP
REAL
_.xx
0.00 %
ro
Output
123.01 INHIBIT
OVER SPEED
TRIP
BOOL
0 : FALSE
1 : TRUE
FALSE
rw
123.02 THRESHOLD
OVER SPEED
TRIP
REAL
0.00 to 300.00 %
150.00 %
rw
123.03 DELAY
OVER SPEED
TRIP
REAL
0.00 to 10.00 s
0.10 s
rw
123.04 TRIPPED
OVER SPEED
TRIP
BOOL
0 : FALSE
1 : TRUE
FALSE
ro
Output
124.01 ENABLE
MOVE TO
MASTER
BOOL
0 : FALSE
1 : TRUE
FALSE
rw
124.02 MOVE METHOD
MOVE TO
MASTER
ENUM
0 : SHORTEST
1 : FORWARD
2 : BACKWARD
SHORTEST
rw
124.03 DIRECTION BAND
MOVE TO
MASTER
REAL
0.00 to 200.00
0.05
rw