19
LT6488 issue 1 (06/13)
Paragon P6
Maintenance Instructions
SECTION TEN Maintenance Continued
REPLACEMENT OF OXY-PILOT ASSEMBLY
NOTE:
If the pilot assembly is replaced it must be replaced by an identical unit from the same
manufacturer and replaced as a complete unit.
Follow the burner tray removal sequence.
Undo the compression nut on the supply pipe at the pilot.
Carefully pull off the ignition lead.
Disconnect the thermocouple at the end of the main control valve.
Remove the cross headed nut holding the pilot to the chassis
Carefully remove the oxy-pilot.
Re-assemble in reverse order.
REPLACEMENT OF THE SPARK GENERATOR
Disconnect leads from control unit.
Re-assemble in reverse order.
FLUE CHECK
Remove the fire from the opening: - Reversing fitting instructions, but first remove fascia and
glass panel plus Log shapes.
Examine flue and rectify as necessary.
Replace the fire, referring to fitting instructions.