SECTION THREE Cleaning

 

 

Warning: -  

Before you clean any part of the appliance ensures that the appliance is turned off and cold. 

 

CLEANING: FASCIA 

Abrasive or chemical cleaner should 

never

 be used. 

 

CLEANING: PAINTED SURFACES 

 

These surfaces should be dusted regularly and any marks removed with a soft cloth. 

 

Abrasive or chemical cleaner should 

never

 be used. 

 

CLEANING: PILOT ASSEMBLY 

(Before cleaning ensure that the appliance is turned off and 
cold)  
In  some  instances  you  may  experience  ignition  problems  even 
when the appliance is new. This may be due to the aeration hole 
in  the  pilot  body  (see  photograph)  being  partial  blocked  with 
dust, pet hairs, or other foreign matter. The source of this debris 
could be such things as carpet fibres, decorating or pets etc. 
To gain access to the pilot, remove the ash pan cover and fret or 
fascia. 
The pilot is located on the right hand side of the appliance, any 
debris  in  or  around  the  aeration  hole  should  be  remove  using 
the  nozzle  of  a  vacuum  cleaner.  It  is  advisable  not  to  blow  the 
debris into the hole as this may cause more of a restriction and 
not rectify the problem. 

Note: - Take care when cleaning in this area so as not to damage the pilot assembly. 

 

GLASS CLEANING 

From time to time it will be necessary to clean the glass panel of your 660 PC fire. We recommend 
you  use  a  Ceramic  hob  cleaner  these  are  available  for  all  leading  super  markets:  -  i.e. 

ASDA, 

TESCO, SAINSBURY’S

 Etc. 

Brands of hob cleaning we have tested and found suitable are - 

HOB BRITE & VITRO CLEAN.  

 

Ensure the fire as been turned OFF for at least four hours to ensure it is cool.

 

 

Remove the glass panel as described below.

 

 

Lay the glass panel down on a flat working surface on top of an old opened newspaper with the 
side to be cleaned uppermost.

 

 

Follow the instructions on the Hob Cleaner Bottle.

 

 

On stubborn stains (where the appliance as been used for a long period without glass panel being 
cleaned), use a new Brillo Pad well wetted with the Hob cleaner applied directly to it.

 

 

Ensure  all  the  residues  of  the  cleaner  are  removed  with  a  damp  cloth  and  the  glass  panel  is 
completely dry before fitting to the appliance.

 

 

Important: - The appliance must not be used if the glass panel is missing or damaged. 

 

Note: - The glass may discolour quickly when first installed, and it should be cleaned.  This is 
due to the burning off process of the refractory shapes. 
 
*The top of the outer firebox is not a working surface and therefore you should avoid placing 
items on top* 
 

Summary of Contents for P6

Page 1: ...NSTRUCTIONS Please read these instructions carefully before you start installing or using this appliance Keep this booklet handy for future reference This appliance is For use in Great Britain or IRELAND only Paragon Fires Charlton Jenrick Ltd TELFORD SHROPSHIRE TF3 3AR ...

Page 2: ...ION INSTRUCTIONS SECTION FIVE Appliance Data 10 SECTION SIX Regulations and Warnings 11 SECTION SEVEN Siting the Appliance Flue Class1 12 Installation Compatibility hole in wall 12 SECTION EIGHT to Install Appliance Checking the Flue and Fire Opening 12 Fitting the closure plate 13 Gas supply routing 13 Mounting the appliance 13 Connect the gas supply 13 Fitting the glass panel 13 SECTION NINE Che...

Page 3: ...otection After handling wash hands and other exposed parts If a vacuum is used for cleaning the coals or cleaning after servicing installation it is recommended that it is of the type fitted with a HEPA filter Disposal of refractory ceramic materials To keep dust to a minimum these materials should be securely wrapped in polythene and be clearly labelled RCF waste These materials are not classifie...

Page 4: ...d conforming to BS 1945 1997 however a fireguard conforming to BS6539 1997 must be used to protect young children the elderly or infirm The appliance MUST NOT be used with the glass safety screen removed or if it is damaged or cracked During initial firing an odour may be evident This is the starch binder used during the manufacture of the fibre components of the fire and there are no harmful effe...

Page 5: ...the battery directly under the spark generator unit The full lighting procedure is as follows a Push slide control lever in as far as possible a clicking noise will be heard and the pilot will light PUSH FIRMLY FOR ABOUT 20 SECONDS b Allow the lever to spring back the pilot light should remain alight and the main burner should light on its low setting c Should the pilot fail to light pull the leve...

Page 6: ...roblem Note Take care when cleaning in this area so as not to damage the pilot assembly GLASS CLEANING From time to time it will be necessary to clean the glass panel of your 660 PC fire We recommend you use a Ceramic hob cleaner these are available for all leading super markets i e ASDA TESCO SAINSBURY S Etc Brands of hob cleaning we have tested and found suitable are HOB BRITE VITRO CLEAN Ensure...

Page 7: ...uts retaining the LH and RH glass panels SECTION FOUR Fuel Bed Cleaning and Layout Use only the fuel bed components provided and no additional parts must added Incorrect positioning of the fuel bed components could result in the staining of the glass panel Important Refer to the Health Safety Notice located on page 3 of this booklet before cleaning or replacing any refractory material The fuel bed...

Page 8: ...ed Place four of the log shapes on top of the air tray touching the glass back liner as shown No 12 No 16 No 16 No 14 Place a single layer of the bark chipping along the front edge of the air tray as shown Place four shapes shown within the burner top plate and air tray as shown No 15 No 14 No 15 No 12 ...

Page 9: ...06 13 Paragon P6Users Instructions SECTION FOUR Fuel Bed Cleaning and Layout Continued Bridge two of the shape as shown No 5 No 8 Bridge two of the shapes as shown No 8 No 15 Bridge two of the shapes as shown No 16 No 4 ...

Page 10: ...ata Badge Location Located on the left hand side of the base of the appliance behind the trim Battery 9 v 1604G 6F22 NOTE The efficiency of this appliance has been measured as specified in BS 7977 1 2009 and the result is 74 1 natural gas The gross calorific value of the fuel has been used for this efficiency calculation Gastec have certified the test data from which it has been calculated The eff...

Page 11: ...y a competent person and installed in accordance with the current edition of I S 813 Domestic Gas Installation the current building regulations and the current ETCI rules for electrical installation if appropriate Prior to the installation ensure that the local distribution conditions identification of type of gas and pressure and adjustment of the appliance are compatible G20 20mbar IMPORTANT NOT...

Page 12: ... a maximum opening of 430mm This allows a 10mm overhang The total width of the closure plate is 520mm and will accommodate a maximum opening of 510mm This allows a 10mm overhang PREPARING THE OPENING CHECKING THE FLUE AND FIRE OPENING Check that the chimney conforms to the required specifications as previously stated Examine the condition and carry out any remedial work including removing any debr...

Page 13: ...mum clearance of 50mm between its open end and the nearest obstruction There must also be a minimum clearance of 100mm between the back of the closure plate and the back of the catchment space Place the fire in position and mark the wall through the holes in the fixing brackets LH and RH of the firebox Drill and plug the holes using no 10 wall plugs Place the fire in position and secure with four ...

Page 14: ... retaining bracket over the five fixing studs and fit and tighten the 7mm nuts making sure again that the glass panel is flush and central Final tighten the four 7mm nuts retaining the LH and RH glass panels BATTERY CONNECTION POSITION Before operating the appliance the battery must be fitted to the spark generator The generator and boot connection is located on the base of the fire box on the rig...

Page 15: ...nts please use only the specified number of components as illustrated Only use fuel bed component provided for this appliance In the interest of safety and efficiency of your appliance when replacing the fuel bed it is essential that the existing fuel bed be removed and the new components are replaced correctly as a complete set Lay fuel bed as described under Users Section Warning It is important...

Page 16: ...sconnect the fire from the gas supply and seek expert advice Spillage can be caused by a restriction in the flue system down draught or insufficient ventilation into the room where the fire is installed FIT STANDARD FASCIA Offer the decorative fascia up squarely and centrally The back face of the fascia will have cut out to give clearance for glass retaining brackets Use these slots as a guide sli...

Page 17: ...be used to protect young children the elderly or infirm The curing effect of heating the logs and other refractory components will cause an initial odour This is due to the starch used in the manufacturing process and is non toxic Any debris should be cleaned from the appliance A vacuum cleaner can be used but only after all the loose logs have been removed The appliance should be serviced annuall...

Page 18: ...from the inlet elbow Remove the operating lever assembly Remove the loose fuel bed components Lift off the decorative fascia Remove the battery from the boot lead and remove the two fixing screws attaching the spark generator to the fire box body Remove the four screws attaching the burner tray to the fire box shelf Pull carefully forward and remove the complete tray assembly For normal servicing ...

Page 19: ...t the pilot Carefully pull off the ignition lead Disconnect the thermocouple at the end of the main control valve Remove the cross headed nut holding the pilot to the chassis Carefully remove the oxy pilot Re assemble in reverse order REPLACEMENT OF THE SPARK GENERATOR Disconnect leads from control unit Re assemble in reverse order FLUE CHECK Remove the fire from the opening Reversing fitting inst...

Page 20: ...t be installed by a Gas Safe registered person 2 The appliance must be used in accordance with the user s instructions 3 The appliance must be serviced annually by a Gas Safe registered person 4 The service log must be correctly filled out and the record of annual services must be up to date and supported by receipts in each case 5 This warranty is not transferable and relates to the original inst...

Page 21: ...the helpdesk Model Paragon P6 Serial No This information can be found on the label attached to the packaging and on the data badge which is located on the left hand side of the base of the appliance behind trim Retailer Name ___________________________________________ Address ________________________________ ___________________________________________ ___________________________________________ Da...

Page 22: ...ate of First annual service Engineer Name Gas Safe Registration No Date of Second annual service Engineer Name Gas Safe Registration No Date of Third annual service Engineer Name Gas Safe Registration No Date of Fourth annual service Engineer Name Gas Safe Registration No We may introduce modifications to products from time to time and consequently the details given in this booklet are subject to ...

Page 23: ...TAILS Name ________________________________ Address ________________________________ Post Code TELEPHONE No PRODUCT DETAILS Model Paragon P6 Serial No Date of Purchase This information can be found on the label attached to the packaging and on the data badge which is located on the left hand side of the base of the appliance behind trim WHERE DID YOU PURCHASE THIS PRODUCT Name ____________________...

Page 24: ... Restrictor Label Air Tray Part No 6081 Glass Panels 2 x side 1 x Front Log Fuel Bed 6343 9v Battery 1904 Control Knob Kit Bagged 6291 Spare Fixings A 0411 Closure plate Outer Fascia Data Badge Warning Label 1409 ID Label Packing Labels Grommet 1092 7mm Nut Spinner Beige chippings 46g Part No 6461 Serial Number Inspector ...