C. Cross-Connecting Ports
8799-A2-GB20-10
April 2003
C-5
Cross-Connect Procedure Example
The following information shows an example of cross-connecting four 8799 line
cards.
Procedure
1. Configure Card 1 G.703 ports for DS0 cross connections using the Set Cross
Connect Mode screen. Follow this menu selection sequence:
Main Menu
→
Configuration
→
Current Configuration
→
Cross-Connect
→
Set Cross-Connect Mode
When the screen is first displayed, all ports are set to DS1 Bypass mode.
Change all ports to
DS0 Cross-connect
.
2. Assign time slots to the DSL interfaces using the Assign Time Slots screen. To
access this screen, either select
Assign_DS0s
on the Cross-Connect Mode
screen, or follow this menu selection sequence:
Main Menu
→
Configuration
→
Current Configuration
→
Cross-Connect
→
Assign Time Slots
main/config/xconnect_mode
Slot: 18 Model: 8799
CROSS CONNECT MODE
Source Destination
G.703 MODE DSL
1 DS0 Cross-connect 1,2,3,4,5,6,7,8
2 DS0 Cross-connect Unassigned
3 DS0 Cross-connect Unassigned
4 DS0 Cross-connect Unassigned
5 DS0 Cross-connect Unassigned
6 DS0 Cross-connect Unassigned
7 DS0 Cross-connect Unassigned
8 DS0 Cross-connect Unassigned
Assign_DS0s
-------------------------------------------------------------------------------
Ctrl-a to access these functions, ESC for previous menu MainMenu Exit
Save Clear_All