C. Cross-Connecting Ports
C-4
April 2003
8799-A2-GB20-10
Setting the Cross-Connect Modes
To access the Set Cross-Connect Mode screen, follow this menu selection
sequence:
Main Menu
→
Configuration
→
Current Configuration
→
Cross-Connect
→
Set Cross-Connect Mode
When the screen is first displayed, all ports are set to DS1 Bypass mode. In this
example, Ports 1 and 2 have been changed to
DS1 Bypass
, and
Ports 4–8 have been changed to
DS0 Cross-connect
.
Unassigned
appears
next to Port 3 because time slots associated with the cross-connection have not
yet been assigned.
main/config/xconnect_mode
Slot: 18 Model: 8799
CROSS CONNECT MODE
Source Destination
G.703 MODE DSL
1 DS1 Bypass 1
2 DS1 Bypass 2
3 Unassigned
4 DS0 Cross-connect 3
5 DS0 Cross-connect
6 DS0 Cross-connect
7 DS0 Cross-connect
8 DS0 Cross-connect 5, 6, I
Assign_DS0s
-------------------------------------------------------------------------------
Ctrl-a to access these functions, ESC for previous menu MainMenu Exit
Save Clear_All