Operation
3-7
3160-A2-GB21-80
March 1999
Table 3-2.
Network Interface LEDs (2 of 2)
Name
Meaning
Color
ALRM
Yellow
Indicates whether an alarm condition exists on the received
network signal.
ON :
An alarm condition (LOS, LOF, EER, Yellow, AIS) exists
on the received network signal. Use the Device Health
and Status command to determine the alarm type.
OFF :
No alarm condition exists on the network interface
signal.
EER
Yellow
Indicates the Excessive Error Rate (EER) has been exceeded
on the network interface.
NOTE:
This LED is only valid when ESF framing is being
used.
ON :
The EER has been exceeded on the network interface.
OFF :
The EER has not been exceeded on the network
interface.
NOTE:
The DTE Drop/Insert (DSX-1) interface is only available on 2-port and 4-port
DSU/CSUs.
Table 3-3.
DTE Drop/Insert (DSX-1) Interface LEDs (1 of 2)
Name
Color
Meaning
SIG
Green
Monitors the signal being received from the DTE Drop/Insert
(DSX-1) interface.
ON :
A recoverable signal is being received from the DTE
Drop/Insert (DSX-1) interface.
OFF :
The signal cannot be recovered from the DTE
Drop/Insert (DSX-1) interface (a Loss of Signal
condition exists).
OOF
Yellow
Monitors Out Of Frame (OOF) conditions on the received DTE
Drop/Insert (DSX-1) signal.
ON :
At least one OOF was detected on the signal during the
sampling period.
OFF :
No OOFs were detected on the signal during the
sampling period.
Summary of Contents for ACCULINK 3160
Page 16: ...About This Guide x 3160 A2 GB21 80 March 1999 This page intentionally left blank...
Page 24: ...Introduction 1 8 3160 A2 GB21 80 March 1999 This page intentionally left blank...
Page 100: ...Operation 3 66 3160 A2 GB21 80 March 1999 This page intentionally left blank...
Page 140: ...Maintenance 4 38 3160 A2 GB21 80 March 1999 This page intentionally left blank...
Page 141: ...A 1 3160 A2 GB21 80 March 1999 Front Panel Menu A...
Page 280: ...Equipment List I 2 3160 A2 GB21 80 March 1999 This page intentionally left blank...