Maintenance
4-24
3160-A2-GB21-80
March 1999
Starting a Payload Loopback
The Payload Loopback command (PLB) loops the received signal on the network
interface back to the network. The signal is looped back as close to the DTE
Drop/Insert (DSX-1) port as possible (after it has passed through the framing
circuitry of the DSU/CSU). Framing CRCs and BPVs are corrected.
496-14316-02
CSU
DSU
NETWORK
INTERFACE
DTE
(DSX-1)
ALL 1s
PLB
PORT 1
PORT 2
ALL 1s
ALL
1s
Procedure
To perform a Payload loopback:
1. From the top-level menu screen, select Test.
2. From the Test screen, select Lpbk.
F1
Test:
Rlpbk Lpbk
Ptrns
F2
F3
3. From the Loopback screen, select PLB.
F1
Loopback:
Abort
LLB
PLB
F2
F3
Test Started
appears on Line 2. If a Payload loopback is already in
progress, the
Already Active
message appears. If an invalid combination
of loopbacks is in progress, the error message
Invld Test Combo
appears
(see
Table 4-8
for valid loopback test combinations).