C. Configuration Options
3150-A2-GB24-10
March 2001
C-19
AltDialDir: None
Next None 1 2 3 4 5 Prev
Alternate Dial-Out Directory for Alarm or Trap. Specifies whether a call that cannot be
completed (busy, no answer, etc.) is retried using an alternate phone number. This affects
calls that are initiated in an attempt to send an alarm or trap message to the modem port
or carrier external communication port device. The alternate phone number to try is
contained in one of the five call directories. If call retry is enabled, the initial call is retried
at the original number once before a call attempt to the alternate number is tried. If the
call is not completed at the alternate number, it is also retried once. The alternate dial-out
option applies to each alarm/trap event. Once a call for an alarm/trap message either
completes or fails all retry attempts, the next alarm/trap attempts to establish a call to the
phone number contained in the alarm directory.
None
–
Specifies that alternate alarm dial-out is not performed if a call cannot be
completed to the telephone number contained in the alarm directory.
1–5
–
Specifies the call directory that contains the phone number to call if a call cannot be
completed to the telephone number contained in the alarm directory.
NOTE: For carrier-mounted CSUs, this configuration option is only available if the
communication port is enabled for an external device.
Err Rate: 10E-4
Next 10E-4 10E-5 10E-6 10E-7 10E-8 10E-9 Prev
Excessive Error Rate Threshold. Sets the error rate threshold that determines if an
Excessive Error Rate (EER) condition is declared. This rate is determined by the ratio of
the number of CRC6 errors to the total number of bits received over a set period of time.
Select from the following:
10E-4 – EER is declared if more than 1,535 CRC6 errors are detected within 10 seconds
(factory default).
10E-5 – EER is declared if more than 921 CRC6 errors are detected within 60 seconds.
10E-6 – EER is declared if more than 92 CRC6 errors are detected within 60 seconds.
10E-7 – EER is declared if more than 9 CRC6 errors are detected within 60 seconds.
10E-8 – EER is declared if more than 41 CRC6 errors are detected in three 15-minute
intervals.
10E-9 – EER is declared if more than 4 CRC6 errors are detected in three 15-minute
intervals.
Table C-5.
Alarm Configuration Options (3 of 4)
Summary of Contents for ACCULINK 3150
Page 1: ...ACCULINK CSU Models 3150 A4 and 3151 Operator s Guide Document No 3150 A2 GB24 10 March 2001...
Page 16: ...About This Guide x March 2001 3150 A2 GB24 10...
Page 28: ...2 Installation 2 8 March 2001 3150 A2 GB24 10...
Page 40: ...3 Using the Front Panel 3 12 March 2001 3150 A2 GB24 10...
Page 66: ...4 Configuration 4 26 March 2001 3150 A2 GB24 10...
Page 74: ...5 Security 5 8 March 2001 3150 A2 GB24 10...
Page 118: ...8 Testing 8 18 March 2001 3150 A2 GB24 10...
Page 120: ...A Front Panel Menu A 2 March 2001 3150 A2 GB24 10...
Page 152: ...C Configuration Options C 30 March 2001 3150 A2 GB24 10...
Page 168: ...E Pin Assignments E 10 March 2001 3150 A2 GB24 10...
Page 192: ...F SNMP MIB Objects F 24 March 2001 3150 A2 GB24 10...
Page 218: ...J Equipment List J 2 March 2001 3150 A2 GB24 10...