Monitoring and Testing
4-26
3166-A2-GB20-20
March 1999
Test Patterns
Use the Test Pattern commands to send, monitor, and abort test patterns.
Available test patterns are:
H
QRSS – A quasi-random signal source approximating live data that can be
monitored for logic errors (on the network and the data ports).
H
1-in-8 – A test pattern consisting of a one (1) followed by seven zeros (on the
network only).
H
511 – A pseudo-random bit sequence (PRBS) that is 511 bits long (on the
data ports only). This is a PRBS 2
9
–1 test.
Sending Test Patterns
Use the Send command to start transmission of a test pattern.
Only one test pattern can be active at a time.
"
Procedure
To send a test pattern:
1. From the top-level menu screen, select Test.
2. From the Test screen, select Ptrns.
F1
Test:
Rlpbk Lpbk
Ptrns
F2
F3
3. From the Patterns screen, select Send.
F1
Patterns:
Abort
Send
Mon
F2
F3
4. From the Patterns Send screen, press F1 to send a QRSS pattern, F2 to
send a 1-in-8 pattern, F3 to send a 511 pattern.
F1
Patterns: Send
QRSS
1in8
511
F2
F3
If you send a 1-in-8 pattern, skip Step 5.
Summary of Contents for 3166 CSU
Page 1: ...ACCULINK 3166 DSU CSU USER S GUIDE Document No 3166 A2 GB20 20 March 1999...
Page 16: ...About This Guide x 3166 A2 GB20 20 March 1999 This page intentionally left blank...
Page 20: ...Introduction 1 4 3166 A2 GB20 20 March 1999 This page intentionally left blank...
Page 68: ...SDCP Operation 3 42 3166 A2 GB20 20 March 1999 This page intentionally left blank...
Page 102: ...SDCP Menu A 2 3166 A2 GB20 20 March 1999 This page intentionally left blank...
Page 140: ...Pin Assignments D 12 3166 A2 GB20 20 March 1999 This page intentionally left blank...
Page 166: ...SNMP MIB Objects E 26 3166 A2 GB20 20 March 1999 This page intentionally left blank...
Page 192: ...Equipment List I 2 3166 A2 GB20 20 March 1999 This page intentionally left blank...