Monitoring and Testing
4-14
3166-A2-GB20-20
March 1999
Troubleshooting
The DSU/CSU is designed to provide you with trouble-free service. However,
Table 4-6 gives you some direction if a problem occurs.
For problems other than those listed in the table, please contact your service
representative.
Table 4-6.
Troubleshooting (1 of 2)
Symptom
Possible Cause
Solutions
No power
1. The power module is not
securely attached.
2. The wall receptacle has no
power.
1. Check the power module
attachment.
2. Check the wall receptacle
power by plugging in some
equipment that is known to be
working.
Power-Up
Self-Test fails
The DSU/CSU has detected an
internal hardware failure.
Contact your service
representative.
Message
LOS at
NET
appears
1. Network cable problem.
2. No signal is being transmitted
at the far-end.
3. Facility problem.
1. Check that the network cable
is securely attached at both
ends.
2. Check the far-end status.
3. Contact your facility provider.
Message
OOF at
Net
appears
1. Incompatible framing format
between the network and the
DSU/CSU.
2. Network cabling problem.
3. Facility problem.
1. Check that the framing format
for the network interface is
correct.
2. Check that the network cable
is securely attached at both
ends.
3. Contact your facility provider.
Message
Yellow at Net
appears
1. Network cable problem.
2. Far-end device has lost
framing sync on the line.
3. Facility problem.
1. Check that your network
cable is securely attached at
both ends.
2. Check the status of the
far-end device.
3. Contact your facility provider.
Message
AIS at Net
appears
1. Upstream device is
transmitting an AIS.
2. The network is transmitting
an AIS.
1. Check the status of the
upstream device(s).
2. Contact your facility provider.
Message
EER at
Net
appears
Facility problem.
Contact your facility provider.
Summary of Contents for 3166 CSU
Page 1: ...ACCULINK 3166 DSU CSU USER S GUIDE Document No 3166 A2 GB20 20 March 1999...
Page 16: ...About This Guide x 3166 A2 GB20 20 March 1999 This page intentionally left blank...
Page 20: ...Introduction 1 4 3166 A2 GB20 20 March 1999 This page intentionally left blank...
Page 68: ...SDCP Operation 3 42 3166 A2 GB20 20 March 1999 This page intentionally left blank...
Page 102: ...SDCP Menu A 2 3166 A2 GB20 20 March 1999 This page intentionally left blank...
Page 140: ...Pin Assignments D 12 3166 A2 GB20 20 March 1999 This page intentionally left blank...
Page 166: ...SNMP MIB Objects E 26 3166 A2 GB20 20 March 1999 This page intentionally left blank...
Page 192: ...Equipment List I 2 3166 A2 GB20 20 March 1999 This page intentionally left blank...