B-1
3166-A2-GB20-20
March 1999
Technical Specifications
B
Overview
The technical specifications for the 3166 DSU/CSU are listed in Table B-1. The
fan module cooling requirements for the 3000 Series Carrier are provided in the
COMSPHERE 3000 Series Carrier Installation Manual.
Table B-1.
ACCULINK Model 3166 DSU/CSU Technical Specifications (1 of 2)
Specifications
Criteria
POWER REQUIREMENTS
Sixteen 3166 DSU/CSUs with SDU,
SDCP, and fan module:
115 Vac power supply
– 48 Vdc power supply
90 to 132 Vac, 60 Hz
±
3
(2.4 amp, 215 watts at 115 Vac)
–
60 to –
40 Vdc (4.7 amps maximum)
POWER CONSUMPTION
6.5 watts per circuit card
NETWORK T1 INTERFACE
Physical Interface (USA)
Physical Interface (Canada)
Framing Format
Coding Format
Line Build-Out (LBO)
ANSI PRM
Bit Stuffing
Yellow Alarm Generation
RJ48C
CA81A (T1 with adapter cable)
D4, ESF
AMI, B8ZS
0.0 dB, –7.5 dB, –15 dB, –22.5 dB
Selectable
FCC Part 68, AT&T TR 62411
Selectable
LOOPBACKS
Standard
Additional
AT&T TR 54016, AT&T TR 62411,
ANSI T1.403.1989
RLB (Repeater Loopback), V.54 Loop 2 and
Loop 3, ANSI T1.403 Annex B Fractional T1
Loopback
Summary of Contents for 3166 CSU
Page 1: ...ACCULINK 3166 DSU CSU USER S GUIDE Document No 3166 A2 GB20 20 March 1999...
Page 16: ...About This Guide x 3166 A2 GB20 20 March 1999 This page intentionally left blank...
Page 20: ...Introduction 1 4 3166 A2 GB20 20 March 1999 This page intentionally left blank...
Page 68: ...SDCP Operation 3 42 3166 A2 GB20 20 March 1999 This page intentionally left blank...
Page 102: ...SDCP Menu A 2 3166 A2 GB20 20 March 1999 This page intentionally left blank...
Page 140: ...Pin Assignments D 12 3166 A2 GB20 20 March 1999 This page intentionally left blank...
Page 166: ...SNMP MIB Objects E 26 3166 A2 GB20 20 March 1999 This page intentionally left blank...
Page 192: ...Equipment List I 2 3166 A2 GB20 20 March 1999 This page intentionally left blank...