Esprit 728 Ultra & 738 Ultra  - 6 -   Programming Guide

*  = Fire zone for 4-wire smoke detectors or 2-wire smoke detectors (with no ATZ enabled—728 Ultra only).
** = Fire zone for 2-wire smoke detectors (address 086, key [

BYP

]) only when ATZ is enabled (address 090, key [8]). Applies only to 728 Ultra.

†  = Zones 1 to 10 for the 728 Ultra and Zones 1 to 18 for the 738 Ultra    

Disarming (Opening) Report Codes (reset code “empty”):                                                                                                   (continued)

Streamline 

Section

Data

Description

Address

Streamline 

Section

Data

Description

Address

___ / ___

User Code 13

364

___ / ___

User Code 29

380

___ / ___

User Code 14

365

___ / ___

User Code 30

381

___ / ___

User Code 15

366

___ / ___

User Code 31

382

___ / ___

User Code 16

367

___ / ___

User Code 32

383

___ / ___

User Code 17

368

___ / ___

User Code 33

384

___ / ___

User Code 18

369

___ / ___

User Code 34

385

___ / ___

User Code 19

370

___ / ___

User Code 35

386

___ / ___

User Code 20

371

___ / ___

User Code 36

387

___ / ___

User Code 21

372

___ / ___

User Code 37

388

___ / ___

User Code 22

373

___ / ___

User Code 38

389

___ / ___

User Code 23

374

___ / ___

User Code 39

390

___ / ___

User Code 24

375

___ / ___

User Code 40

391

___ / ___

User Code 25

376

___ / ___

User Code 41

392

___ / ___

User Code 26

377

___ / ___

User Code 42

393

___ / ___

User Code 27

378

___ / ___

User Code 43

394

___ / ___

User Code 28

379

___ / ___

User Code 44

395

___ / ___

User Code 45

396

___ / ___

User Code 46

397

___ / ___

User Code 47

398

___ / ___

User Code 48 /

(Duress)

399

Alarm Report Codes For Zones 1 to 10 (18) †:

Alarm Restore Report Codes For Zones 1 to 10 (18) †:

Streamline 

Section

Data

Description

Address

Streamline 

Section

Data

Description

Address

___ / ___

Zone 1

400

___ / ___

Zone 1

424

___ / ___

Zone 2

401

___ / ___

Zone 2

425

___ / ___

Zone 3/Fire zone*

(fire address 100)

402

___ / ___

Zone 3/Fire zone*

(fire address 100)

426

___ / ___

Zone 4

403

___ / ___

Zone 4

427

___ / ___

Zone 5/Fire zone**

404

___ / ___

Zone 5/Fire zone**

428

___ / ___

Zone 6

405

___ / ___

Zone 6

429

___ / ___

Zone 7

406

___ / ___

Zone 7

430

___ / ___

Zone 8

407

___ / ___

Zone 8

431

___ / ___

Zone 9

408

___ / ___

Zone 9

432

___ / ___

Zone 10

409

___ / ___

Zone 10

433

___ / ___

Zone 11 

(738 Ultra only)

410

___ / ___

Zone 11 

(738 Ultra only)

434

___ / ___

Zone 12 

(738 Ultra only)

411

___ / ___

Zone 12 

(738 Ultra only)

435

___ / ___

Zone 13

412

___ / ___

Zone 13

436

___ / ___

Zone 14

413

___ / ___

Zone 14

437

___ / ___

Zone 15

414

___ / ___

Zone 15

438

___ / ___

Zone 16

415

___ / ___

Zone 16

439

___ / ___

Zone 17

416

___ / ___

Zone 17

440

___ / ___

Zone 18

417

___ / ___

Zone 18

441

41

Future Use

418 - 423

47

Future Use

442 - 447

27

31

28

32

29

33

30

34

35

36

42

37

43

38

44

39

738 Ultra 

only

45

738 Ultra 

only

40

738 Ultra only

46

738 Ultra only

    

Summary of Contents for Esprit 728 Ultra

Page 1: ...728 Ultra With ATZ 738 Ultra No ATZ 738 Ultra With ATZ Control Panel Input 1 Zone 1 Zones 1 2 Zone 1 Zones 1 9 Input 2 Zone 2 Zones 3 4 Zone 2 Zones 2 10 Input 3 Zone 3 Zones 5 6 Zone 3 Zones 3 11 Inp...

Page 2: ...Auxiliary Current 11 Fire Loop Trouble Table 4 Hex Programming Method 1 Press ENTER INSTALLER CODE default 728 Ultra 282828 738 Ultra 383838 2 The ENTER key will flash indicating you are in programmi...

Page 3: ...ts are programmed 02 __ __ __ __ __ __ __ __ 03 __ __ __ __ __ __ __ __ 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 Monitoring Station Telephone Number 1 View at addresses 016 to 023 Streamline Section Str...

Page 4: ...SOUNDER RELAY TROUBLE 2 8 116 DUCT 2ND 8 321 BELL 1 TROUBLE 2 9 117 FLAME 2ND 9 323 ALARM RELAY TROUBLE 2 0 118 NEAR ALARM 2ND 0 350 COMMUNICATION TROUBLE 2 STAY 120 PANIC ALARM 2ND STAY 351 TELCO 1...

Page 5: ...___ ___ User Code 8 309 ___ ___ User Code 32 333 ___ ___ User Code 9 310 ___ ___ User Code 33 334 ___ ___ User Code 10 311 ___ ___ User Code 34 335 ___ ___ User Code 11 312 ___ ___ User Code 35 336 __...

Page 6: ...93 ___ ___ User Code 27 378 ___ ___ User Code 43 394 ___ ___ User Code 28 379 ___ ___ User Code 44 395 ___ ___ User Code 45 396 ___ ___ User Code 46 397 ___ ___ User Code 47 398 ___ ___ User Code 48 D...

Page 7: ...ddress Streamline Section Data Description Address ___ ___ Max aux current 496 ___ ___ Fire loop trouble 500 ___ ___ Bell disconnect max bell current 497 ___ ___ Timer loss 501 ___ ___ Battery disconn...

Page 8: ...est report between 000 and 059 738 Ultra only minutes If address 046 255 and the system is disarmed Disarmed Test Report between 001 and 255 000 049 ___ ___ ___ seconds Exit delay 60 seconds 050 ___ _...

Page 9: ...ess the ENTER key to accept there will be a confirmation beep indicating the options have been accepted The ENTER key will flash to indicate that the software is awaiting the next address entry 5 Retu...

Page 10: ...cy timer in days U 3 N In hours Restrict arming on battery failure U 4 N Enabled Restrict arming on tamper trouble U 5 N Enabled No tamper bypass U 6 N Tamper follows zone bypass definition Zone doubl...

Page 11: ...N N N N N N SYSTEM A STAY if ON zone is armed on Stay or System A arming Zone 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 116 116 N N N N N N N N N N N N 118 N N N N N N SYSTEM B if ON zone is armed...

Page 12: ...ire Fault Recognition UL cUL Address 088 MEM ON EOL resistor disabled 0 OFF STAY OFF Address 090 8 OFF ATZ disabled Tamper Wire Fault disabled Address 088 MEM OFF EOL resistor enabled 0 OFF STAY OFF A...

Page 13: ...dress 088 MEM ON EOL resistor disabled 0 OFF STAY OFF Address 090 8 ON ATZ enabled 7 OFF ATZ wiring in serial Tamper Wire Fault disabled Address 088 MEM ON EOL resistor disabled 0 See Tamper Wire Faul...

Page 14: ...e 2 wire smoke detector and zone 6 will be disabled automatically 2 Wire Smoke Detector Fire Reset Simultaneously press and hold for 3 seconds the ENTER and CLEAR keys on any keypad to conduct a 30 se...

Page 15: ...he system AUX POWER 450mA maximum UL cUL 250mA maximum for 24Hr Stand by To connect additional wiring to the auxiliary power use the red and the black keypad connectors AUX power will shut down if cur...

Page 16: ...ble Acid Lead or Gel Cell Backup Battery Improper connection may result in damage to the system AUX POWER 500mA maximum 250mA maximum for 24Hr Stand by To connect additional wiring to the auxiliary po...

Page 17: ...sulting from the product s inability to operate Seller obligation and liability under this warranty is expressly limited to repairing or replacing at Seller s option any product not meeting the specif...

Page 18: ...Notes...

Page 19: ......

Page 20: ...paradox com PRINTED IN CANADA 07 2007 7X8ULT EP04...

Reviews: