background image

  

 

Esprit 728 Ultra & 738 Ultra  - 7 -   Programming Guide

  

Zones 1 to 10 (18)† Shutdown Report Codes: 

Tampers 1 to 4, 5 and 7 (8)‡ Report Codes: 

Streamline 

Section

Data

Description

Address

Streamline 

Section

Data

Description

Address

___ / ___

Zone 1

448

___ / ___

Tamper 1 

472

___ / ___

Zone 2

449

___ / ___

Tamper 2

473

___ / ___

Zone 3

450

___ / ___

Tamper 3 

474

___ / ___

Zone 4

451

___ / ___

Tamper 4

475

___ / ___

Zone 5

452

___ / ___

Tamper 5 

476

___ / ___

Zone 6

453

___ / ___

Tamper 6 

(738 Ultra only)

477

___ / ___

Zone 7

454

___ / ___

Tamper 7

478

___ / ___

Zone 8

455

___ / ___

Tamper 8 

(738 Ultra only)

479

___ / ___

Zone 9

456

56 to 59

Future Use

480 - 495

___ / ___

Zone 10

457

___ / ___

Zone 11 

(738 Ultra only)

458

___ / ___

Zone 12 

(738 Ultra only)

459

___ / ___

Zone13

460

† = Zones 1 to 10 for the 728 Ultra and 

Zones 1 to 18 for the 738 Ultra 

___ / ___

Zone 14

461

___ / ___

Zone 15

462

 = Zones 1 to 4, 5 and 7 for 728 Ultra and 

Zones 1 to 8 for 738 Ultra

___ / ___

Zone 16

463

___ / ___

Zone17

464

___ / ___

Zone 18

465

53

Future Use

466 - 471

Trouble Report Codes:

Streamline 

Section

Data

Description

Address

Streamline 

Section

Data

Description

Address

___ / ___

Max. aux. current

496

___ / ___

Fire loop trouble

500

___ / ___

Bell disconnect / 

max. bell current

497

___ / ___

Timer loss

501

___ / ___

Battery disconnect / 

low voltage

498

[2

ND

]

/

[2

ND

]

Future Use

502

___ / ___

Power failure

499

[2

ND

]

/

[2

ND

]

Future Use

503

Trouble Restore Report Codes:

Streamline 

Section

Data

Description

Address

Streamline 

Section

Data

Description

Address

___ / ___

Max. aux. current

504

___ / ___

Fire loop trouble

508

___ / ___

Bell disconnect / 

max. bell current

505

___ / ___

Timer 

programmed

509

___ / ___

Battery disconnect / 

low voltage

506

___ / ___

Tamper / wiring fault

510

___ / ___

Power failure

507

___ / ___

TLM restore

511

Special Report Codes:

Streamline 

Section

Data

Description

Address

Streamline 

Section

Data

Description

Address

___ / ___

Test report

512

___ / ___

Duress

520

___ / ___

Panic 1

513

___ / ___

Closing Delinquency

521

___ / ___

Panic 2

514

[2

ND

]

/

[2

ND

]

Future Use

522

___ / ___

Panic 3

515

[2

ND

]

/

[2

ND

]

Future Use

523

___ / ___

Late to close

516

___ / ___

Login (Espload)

524

___ / ___

No movement

517

___ / ___

Program Change

525

___ / ___

Partial Arming

518

[2

ND

]

/

[2

ND

]

Future Use

526

___ / ___

Recent Close

519

[2

ND

]

/

[2

ND

]

Future Use

527

48

54

49

55

50

51

738 Ultra 

only

52

738 Ultra only

60

61

62

63

64

66

65

67

Summary of Contents for Esprit 728 Ultra

Page 1: ...728 Ultra With ATZ 738 Ultra No ATZ 738 Ultra With ATZ Control Panel Input 1 Zone 1 Zones 1 2 Zone 1 Zones 1 9 Input 2 Zone 2 Zones 3 4 Zone 2 Zones 2 10 Input 3 Zone 3 Zones 5 6 Zone 3 Zones 3 11 Inp...

Page 2: ...Auxiliary Current 11 Fire Loop Trouble Table 4 Hex Programming Method 1 Press ENTER INSTALLER CODE default 728 Ultra 282828 738 Ultra 383838 2 The ENTER key will flash indicating you are in programmi...

Page 3: ...ts are programmed 02 __ __ __ __ __ __ __ __ 03 __ __ __ __ __ __ __ __ 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 Monitoring Station Telephone Number 1 View at addresses 016 to 023 Streamline Section Str...

Page 4: ...SOUNDER RELAY TROUBLE 2 8 116 DUCT 2ND 8 321 BELL 1 TROUBLE 2 9 117 FLAME 2ND 9 323 ALARM RELAY TROUBLE 2 0 118 NEAR ALARM 2ND 0 350 COMMUNICATION TROUBLE 2 STAY 120 PANIC ALARM 2ND STAY 351 TELCO 1...

Page 5: ...___ ___ User Code 8 309 ___ ___ User Code 32 333 ___ ___ User Code 9 310 ___ ___ User Code 33 334 ___ ___ User Code 10 311 ___ ___ User Code 34 335 ___ ___ User Code 11 312 ___ ___ User Code 35 336 __...

Page 6: ...93 ___ ___ User Code 27 378 ___ ___ User Code 43 394 ___ ___ User Code 28 379 ___ ___ User Code 44 395 ___ ___ User Code 45 396 ___ ___ User Code 46 397 ___ ___ User Code 47 398 ___ ___ User Code 48 D...

Page 7: ...ddress Streamline Section Data Description Address ___ ___ Max aux current 496 ___ ___ Fire loop trouble 500 ___ ___ Bell disconnect max bell current 497 ___ ___ Timer loss 501 ___ ___ Battery disconn...

Page 8: ...est report between 000 and 059 738 Ultra only minutes If address 046 255 and the system is disarmed Disarmed Test Report between 001 and 255 000 049 ___ ___ ___ seconds Exit delay 60 seconds 050 ___ _...

Page 9: ...ess the ENTER key to accept there will be a confirmation beep indicating the options have been accepted The ENTER key will flash to indicate that the software is awaiting the next address entry 5 Retu...

Page 10: ...cy timer in days U 3 N In hours Restrict arming on battery failure U 4 N Enabled Restrict arming on tamper trouble U 5 N Enabled No tamper bypass U 6 N Tamper follows zone bypass definition Zone doubl...

Page 11: ...N N N N N N SYSTEM A STAY if ON zone is armed on Stay or System A arming Zone 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 116 116 N N N N N N N N N N N N 118 N N N N N N SYSTEM B if ON zone is armed...

Page 12: ...ire Fault Recognition UL cUL Address 088 MEM ON EOL resistor disabled 0 OFF STAY OFF Address 090 8 OFF ATZ disabled Tamper Wire Fault disabled Address 088 MEM OFF EOL resistor enabled 0 OFF STAY OFF A...

Page 13: ...dress 088 MEM ON EOL resistor disabled 0 OFF STAY OFF Address 090 8 ON ATZ enabled 7 OFF ATZ wiring in serial Tamper Wire Fault disabled Address 088 MEM ON EOL resistor disabled 0 See Tamper Wire Faul...

Page 14: ...e 2 wire smoke detector and zone 6 will be disabled automatically 2 Wire Smoke Detector Fire Reset Simultaneously press and hold for 3 seconds the ENTER and CLEAR keys on any keypad to conduct a 30 se...

Page 15: ...he system AUX POWER 450mA maximum UL cUL 250mA maximum for 24Hr Stand by To connect additional wiring to the auxiliary power use the red and the black keypad connectors AUX power will shut down if cur...

Page 16: ...ble Acid Lead or Gel Cell Backup Battery Improper connection may result in damage to the system AUX POWER 500mA maximum 250mA maximum for 24Hr Stand by To connect additional wiring to the auxiliary po...

Page 17: ...sulting from the product s inability to operate Seller obligation and liability under this warranty is expressly limited to repairing or replacing at Seller s option any product not meeting the specif...

Page 18: ...Notes...

Page 19: ......

Page 20: ...paradox com PRINTED IN CANADA 07 2007 7X8ULT EP04...

Reviews: