Operation manual of solar controller SR658
Page 66 of 105
Function set:
►Press “SET” button to select main menu “LLOGI”
►Press “SET” button, “PRIO 1” displays on the screen (here take PRIO 1 as example)
►Press “SET” button, “1” blinks on the screen
►Press “↑”, “↓” button, to select tank priority logic
►Press “SET” or “ESC” button, to confirm the setting
►Press “↑”, “tLB 2min” displays on the screen
►Press “SET” button, “2min” blinks on the screen
►Press “↑”, “↓” button, to adjust the runtime of heating
►Press “SET” or “ESC” button, to confirm the setting
►Press “↑”, “tRUN 15min” displays on the screen
►Press “SET” button, “15min” blinks on the screen
►Press “↑”, “↓” button, to adjust the stop time of heating
►Press “SET” or “ESC” button, to confirm the setting
►Press “↑”, “OSTS OFF” displays on the screen
►Press “SET” button, “OFF” blinks on the screen
►Press “↑”, “↓” button, to activate tank temperature set function
►Press “SET” or “ESC” button, to confirm the setting
►Press “↑”, “TST1 45
o
C
” displays on the screen
►Press “SET” button, “45
o
C
” blinks on the screen
►Press “↑”, “↓” button, to adjust the temperature of tank 1
►Press “SET” or “ESC” button, to confirm the setting
►Press “↑”, “TST2 45
o
C
” displays on the screen
►Press “SET” button, “45
o
C
” blinks on the screen
►Press “↑”, “↓” button, to adjust the temperature of tank 2
►Press “SET” or “ESC” button, to confirm the setting
►Press “↑”, “OSE OFF” displays on the screen
►Press “SET” button, “OFF” blinks on the screen
►Press “↑”, “↓” button, to activate spread loading function
►Press “SET” or “ESC” button, to confirm the setting
►Press “↑”, “DTSE 40K” displays on the screen
►Press “SET” button, “40K” blinks on the screen
►Press “↑”, “↓” button, to adjust the spread temperature difference
►Press “SET” or “ESC” button, to confirm the setting
►Press “↑”, “PDELR OFF” displays on the screen