Operation manual of solar controller SR658
Page 59 of 105
►Press “↑”, “↓” button to adjust the runtime (unit: second)
►Press “SET” or “ESC” button, to confirm the setting
►Press “↑”, “TCIN 30Min” displays on the screen
►Press “SET” button, runtime “30” blinks
►Press “↑”, “↓” button to adjust the stop time (unit: second)
►Press “SET” or “ESC” button, to confirm the setting
►Press “ESC” button to return to the previous menu
(
10
)
PINTV Swimming pool function
This function is designed to improve the operation of swimming pool system, in which sensor
position is not ideal.
This function operates within a pre-set time - section. It activates the swimming pool circuit
pump R1 or R2 intermittently to compensate for the delayed temperature measurement
caused by poor sensor position.
If the runtime is set to more than 10s, the pump will run at 100% speed during the first 10s,
and pump will run at the minimum speed during the remaining runtime.
Menu structure
Main menu
Submenu
Default
set
Adjust
range
Adjust
step
Description
PINTV
Swimming pool function
tPST
00:00
00:00-23:59 30min
Start time of swimming pool
function
tPEN
23:59
00:00-23:59 30min
Stop time of swimming pool function
tPRU
30S
30-300s
5s
Runtime of swimming pool function
tPIN
30MIN
5-60min
1min
Stop time of swimming pool function