Operation manual of solar controller SR658
Page 41 of 105
Main
menu
Submenu 1
Submenu
2
Default set
Adjust range
Adjust step
THET
Timed heating function
ELECT
OFF
ON/OFF
Electrical back-up heat producer
BOILE
OFF
ON/OFF
Boiler
as
back-up
heater
producer
THTS
T3
T2
,
T3
Selection of the target sensor
for timed heating function
SMT
OFF
ON/OFF
Intelligent heating
tH1O
04:00/40
℃
00:00-23:59/0.0-93
℃
Start time and switch-on
temperature for the first time-
section
tH1F
05:00/50
℃
00:00-23:59/2-95
℃
Close time and switch-off
temperature for the first time-
section
t H2O
10:00/40
℃
00:00-23:59/0.0-93
℃
Start time and switch-on
temperature for the second
time - section
tH2F
10:00/50
℃
00:00-23:59/2-95
℃
Close time and switch-off
temperature for the second
time - section
tH3O
17:00/50
℃
00:00-23:59/0.0-93
℃
Start time and switch-on
temperature for the third time-
section
tH3F
22:00/55
℃
00:00-23:59/2-95
℃
Close time and switch-off
temperature for the third time-
section
Function set:
►Press “SET” button, access main menu, press “↑” button to
select THET timed heating menu
►Press “SET” button, access the submenu of setting
interface,
“ELECT” displays on the screen (take ELECT as
example)
►Press “SET” button, “ELECT OFF” displays
►Press “SET” button, “OFF” blinks
►Press “↑”, “↓” button to activate the function, “ELECT ON” displays on the screen
►Press “SET” or “ESC” button, to confirm the setting
►Press “↑”, to access sensor selection window, “THTS T3” displays on the screen
►Press “SET” button, “T3” blinks
►Press “↑”, “↓” button to select the available sensor