Operation manual of solar controller SR658
Page 45 of 105
Note:
Installed a check valve to avoid the water which is from tank mixing with water from
circuit pipe.
If the stop time is set with value 0 minute, then when flow switch feels the flow and
thus to trigger the pump, pump will run for the whole time - section. And when the
stopcock is closed, pump is stopped automatically.
Default time - section set:
The first time - section: start at 05:00 and stops at 07:00a.m
The second time - section: starts at 11:00 and stops at 13:00
The third time - section: starts at 17:00 and stops at 22:00 p.m.
Flow switch fitting:
Material of fitting: brass
House: plastic
Connection: G3/4
Reed of flow switch: Max 300V DC/1A
Note:
Noting the flow direction indicated on the flow switch!
Flow switch is not included in the delivery list of this controller, please buy it separately.