566
DP-C405/C305/C265
FEB 2008
Ver. 1.1
024 CED Frequency
1080 Hz (non ITU-T)
2100 Hz
Selects the CED frequency 2100/1080 Hz
025 COMM. Start-Up
First
Second
Selects the communication start-up condition (XMT
and Polling).
(Used when Echo Suppression is disabled.)
026 Non-Standard
Off (Invalid)
On (Valid)
Selects own mode (Panafax mode).
027 Short Protocol B
Off (Invalid)
On (Valid)
Selects the short protocol mode.
028 Short Protocol D
Off (Invalid)
On (Valid)
Selects the short protocol mode. When activated, it
allows the machine to automatically store the modem
speed for each Auto Dial Number.
029 Remote
Diagnostics
Off (will not accept)
On (accepts)
Selects whether the machine accepts Remote
Diagnostics from the service station.
030 CED & 300 bps
75 ms
1 sec
Selects the pause interval between the CED, and the
300 bps signal.
(Used when Echo Suppression is disabled.)
031 RTC = EOL x 12
Off (EOLx6)
On (EOLx12)
Selects the RTC signal, EOLx6 or EOLx12.
032 V34 TX Start
2400-33600bps
Selects the transmission modem start speed for V.34
communication, 33600-2400 bps.
Press “
” or “
“ to select the symbol rate.
033 V34 RX Start
2400-33600bps
Selects the receiving modem start speed for V.34
communication, 33600-2400 bps.
Press “
” or “
“ to select the symbol rate.
034 V34 TX SR
2400-3429sr
Selects the transmission symbol rate for V.34, 3429/
3200/3000/2800/2400 sr.
Press “
” or “
“ to select the symbol rate.
035 V34 RX SR
2400-3429sr
Selects receiving symbol rate for V.34, 3429/3200/
3000/2800/2400 sr.
Press “
” or “
“ to select the symbol rate.
036 Not Used
037 Protocol Display
Off (not displayed)
On (displayed)
Selects whether to display the modem speed during
communication.
(Press the Job Status Key to display)
038 Not Used
039 Flash Time
50 ms
~
1000 ms
Selects the pause interval before activating the Flash
key.
040 Flash Time
(PSTN)
50 ms
~
1000 ms
Selects the pause interval before activating the Flash
key.
(For Germany, Austria and Czech)
041 Pause Time
1 = 1 sec.
~
10 = 10 sec.
Selects the pause interval from 1 sec. ~ 10 sec. for
dialing through a switchboard, or for international
calls.
042 Not Used
043 Redial Interval
0 = no waiting
~
15 = 15 minutes
Selects the redial interval from 0 to 15 minutes in 1
minute steps.
Function Parameter Table
No.
Parameter
Selections
Function
Summary of Contents for Workio DP-C305
Page 2: ...2...
Page 3: ...3...
Page 5: ...5...
Page 6: ...6 For PB and Other Destinations not for PU USA Canada...
Page 11: ...11...
Page 12: ...12...
Page 13: ...13...
Page 14: ...14 memo...
Page 220: ...220 FEB 2008 Ver 1 1 DP C405 C305 C265 Color Test Chart 101 P N PJQRC0119Z LDR PJQRC0120Z A3...
Page 232: ...232 FEB 2008 Ver 1 1 DP C405 C305 C265 3 20 720K PM Kit DQ M35S72 DQ M32N72...
Page 400: ...400 FEB 2008 Ver 1 1 DP C405 C305 C265 LVPS CN6 LVPS CN7 Refer to SCN PC Board...
Page 401: ...401 FEB 2008 Ver 1 1 DP C405 C305 C265 LVPS CN8 Europe Specification Only...
Page 404: ...404 FEB 2008 Ver 1 1 DP C405 C305 C265 CST PCB CN603 CST PCB CN604...
Page 405: ...405 FEB 2008 Ver 1 1 DP C405 C305 C265 CST PCB CN605...
Page 406: ...406 FEB 2008 Ver 1 1 DP C405 C305 C265...
Page 407: ...407 FEB 2008 Ver 1 1 DP C405 C305 C265 CST PCB CN606...
Page 408: ...408 FEB 2008 Ver 1 1 DP C405 C305 C265...
Page 409: ...409 FEB 2008 Ver 1 1 DP C405 C305 C265 CST PCB CN607...
Page 410: ...410 FEB 2008 Ver 1 1 DP C405 C305 C265 CST PCB CN608...
Page 412: ...412 FEB 2008 Ver 1 1 DP C405 C305 C265 TRU PCB CN613...
Page 414: ...414 FEB 2008 Ver 1 1 DP C405 C305 C265 RLB PCB CN176...
Page 615: ...615 DP C405 C305 C265 FEB 2008 Ver 1 1 1 2 3 4 5 6 7 8...
Page 752: ...752 FEB 2008 Ver 1 1 DP C405 C305 C265 memo...
Page 847: ...847 DP C405 C305 C265 FEB 2008 Ver 1 1 2 Motor PCBs Fig 5 009 M1 M2 M8 M5 M4 M3 M7 M6 1...
Page 919: ......
Page 920: ...Published in Japan...