62
Operation and configuration when connecting
the recorders in cascading connection
When connecting the recorders (up to 5 recorders) in cascading connection, all images managed by the con-
nected recorders can be monitored on a single monitor.
The following are descriptions of how to operate when the recorders are connected in cascading connection. To
operate the recorders connected in cascading connection, it is necessary to configure the settings in advance.
Refer to the Installation Guide for further information.
Important:
• Audio cables can also be connected in cascading connection.
Configuration
Configure the settings required for cascading connection. Operations and settings of the WJ-HD716K are the
same as that of the WJ-HD616K.
For WJ-HD616K
Select "On" for "Cascade" on the "Cascade" tab under "Display" of the setup menu of the recorder to be con-
nected in cascading connection. Set the unit addresses of recorders as follows.
WJ-HD616K
Unit address (system)
Unit address (controller)
First recorder
001
Select a number except 001 - 004 and not used
for the other devices.
Second recorder
002
Third recorder
003
Fourth recorder
004
Fifth recorder
005
Settings of a system controller
Set the unit addresses of system controllers as follows.
System controller
Unit address
Remarks
First system controller
001
It is possible to operate all monitor 1 and monitor
2 connected to the first through fifth WJ-HD616K.
Second system controller
002
Monitor 1 and monitor 2 connected to the first
through the fifth WJ-HD616K are available to oper-
ate. However, camera selection on monitor 2 is
unavailable.
Third system controller
003
Fourth system controller
004