15
English
●
If there is a lead wire within approx. 3 mm from the
end face of the circuit board, the function board
cannot be attached due to interference with the guide
rail. Ensure that there is no lead wire in this range.
Approx. 3 mm
No lead wire in this range.
Circuit board
4
Remove the 2 screws from the main
unit slot cover.
Cover
Screw
5
Insert the function board to the main
unit slot, and fix it with the 2 screws
removed in step 4.
Cautions when
moving
The display has handles for carrying. Hold them when
moving.
75-inch model
Handle
65-inch model
Handle
Note
●
Do not hold parts other than the handles.
●
The following number of people are required to carry
this unit.
75-inch model
: 4 or more
65-inch model
: 2 or more
If this is not observed, the unit may drop, resulting in
injury.
●
When carrying the unit, keep the front panel upright.
Carrying the unit with the surface of the front panel
facing up or down may cause deformation of the
panel, or internal damage.
●
Do not hold the upper, lower, right and left frames or
the corners of the unit. Do not hold the front surface
of the panel. Also, do not hit such parts.
Doing so may damage the liquid crystal panel.
Also, the panel may crack, resulting in injury.