107
English
■
[No signal error timing]
Set up the detecting time for no signal error.
(Range: 01 ‒ 90, Interval: 1 minute)
●
The warning of [No signal warning] and the error
of [No signal error] are not sent when the no signal
state is detected through any of the following
functions:
[No signal power off], [HDMI1 power management],
[HDMI2 power management], [HDMI3 power
management], [DisplayPort power management],
[DVI-D power management], [PC power
management] (see page 89)
Setting Example:
●
If there is no signal when [PC IN] is input, [PC
power management] is activated first and the
Display enters the standby mode.
[No signal warning timing]: 5 minutes
[No signal error timing]: 10 minutes
[PC power management]: [On] (60 seconds)
Note
●
The [No signal error timing] cannot be set
shorter than [No signal warning timing].
●
Even when a USB memory is connected, if
there is no playable file, the unit determines no
signal is present.
■
[Temperature warning]
When set to [On], the display sends out the warning
message.
SLOT settings
Set for SLOT.
This menu is displayed only when a function board is
inserted into the SLOT.
Depending on the type of a function board, disabled
items are greyed out.
[SLOT settings] - submenu screen
SLOT settings
SLOT power link
Off
SLOT power on
SLOT forced termination
SLOT information
SLOT standby
On
■
[SLOT information]
Displays the information of the function board inserted
to the SLOT.
■
[SLOT power link]
Links the power operation of the SLOT with the power
operation of this unit.
[Off]:
Does not link.
[On]:
The power of the unit is turned off when the power
of the inserted function board is turned off during
SLOT input or enters the power save mode. After
that, when the power of the function board is
turned on or returns from the power save mode,
the power of the unit is turned on.
Note
●
When [HDMI-CEC control] is set to [Enable], this
menu will be greyed out and cannot be set. (see page
91)
■
[SLOT standby]
Sets the power supply status for the SLOT when the
unit is in standby mode.
[Off]:
The power is not supplied to the SLOT when the
power is turned off by the remote control, etc.
[On]:
The power is supplied to the SLOT when the
power is turned off by the remote control, etc.
Note
●
When [SLOT standby] is set to [On], the power
indicator in standby mode lights purple.
■
[SLOT power on]
Starts up the power of the SLOT.
■
[SLOT forced termination]
Forcibly turns off the power of the SLOT. Use this only
when the power cannot be turned off manually due to
the problem of the operating system, etc.
Maximum VOL function
Enables/Disables [Maximum VOL function].
[Off]:
The sound volume level can be set up to 100
(maximum).
[On]:
The volume cannot be set to the level higher than
the level set for [Maximum VOL level].