Default Value
16000
Web User Interface Reference
RTP_PORT_MAX
Value Format
INTEGER
Description
Specifies the highest port number that the unit will use for RTP
packets.
Value Range
1424–59998 (only even)
Default Value
20000
Web User Interface Reference
RTP_PTIME
Value Format
INTEGER
Description
Specifies the interval, in milliseconds, between transmissions of RTP
packets.
Value Range
•
20
•
30
•
40
•
60
Default Value
20
Web User Interface Reference
RTCP_ENABLE_n
For details about parameter names end with "_n", see 5.2.1 Configuration File Parameters
Value Format
BOOLEAN
Description
Specifies whether to enable or disable RTCP (Real-Time Transport
Control Protocol). For details, refer to RFC 3550.
Value Range
•
Y
: Enable RTCP
•
N
: Disable RTCP
Default Value
N
Web User Interface Reference
RTCP_INTVL_n
For details about parameter names end with "_n", see 5.2.1 Configuration File Parameters
Value Format
INTEGER
Description
Specifies the interval, in seconds, between RTCP/RTCP-XR packets.
Value Range
5–65535
Default Value
5
Web User Interface Reference
5.3.26 RTP/RTCP/RTCP-XR Settings