Description
Specifies the duration, in seconds, that a disconnect tone will be
heard when the other party ends a call and the unit is being used.
Value Range
1–15 (s)
Default Value
3
DIAL_TONE1_FRQ
Value Format
Comma-separated Integer
Description
Specifies the dual-tone frequencies, in hertz, of Dial Tone 1 using 2
whole numbers separated by a comma.
Value Range
0, 200–2000 (Hz) (0: No tone)
Default Value
350,440
Web User Interface Reference
DIAL_TONE1_GAIN
Value Format
INTEGER
Description
Specifies the gain, in decibels, of Dial Tone 1.
Value Range
-24–24 (dB)
Default Value
0
DIAL_TONE1_RPT
Value Format
INTEGER
Description
Specifies whether Dial Tone 1 is repeated.
Value Range
0–1
–
0: No Repeat
–
1: Repeat
Default Value
0
DIAL_TONE1_TIMING
Value Format
Comma-separated Integer
Description
Specifies the pattern, in milliseconds, of Dial Tone 1 using up to 10
whole numbers (off 1, on 1, off 2, on 2…) separated by commas.
Note
•
It is recommended that you set a value of 60 milliseconds or
more for the first value (off 1).
Value Range
0–16000 (msec) (0=Continuous)
Note
•
Avoid setting 1–50 for any of the values.
Default Value
60,0
Web User Interface Reference
5.3.33 Tone Settings
320
Administrator Guide
Document Version: 2017-07