Tone Timings
Description
Specifies the pattern, in milliseconds, of dial tones using up to 10
whole numbers (off 1, on 1, off 2, on 2…) separated by commas.
Note
•
The unit will not play the tone for the duration of the first value,
play it for the duration of the second value, stop it for the
duration of the third value, play it again for the duration of the
fourth value, and so on. The whole sequence will then repeat.
For example, if the value for this setting is "100,100,100,0", the
unit will not play the tone for 100 ms, play it for 100 ms, stop it
for 100 ms, and then play it continuously.
•
It is recommended that you set a value of 60 milliseconds or
more for the first value (off 1).
Value Range
0–16000 (0: Infinite time)
Note
•
Avoid setting 1–50 for any of the values.
Default Value
60,0
Configuration File Reference
4.6.6.2 Busy Tone
Tone Frequencies
Description
Specifies the dual-tone frequencies, in hertz, of busy tones using 2
whole numbers separated by a comma.
Value Range
0, 200–2000 (0: No tone)
Note
•
If the value for this setting is "480,620", the unit will use a
mixed signal of a 480 Hz tone and a 620 Hz tone.
Default Value
480,620
Configuration File Reference
Tone Timings
Description
Specifies the pattern, in milliseconds, of busy tones using up to 10
whole numbers (off 1, on 1, off 2, on 2…) separated by commas.
Value Range
0–16000 (0: Infinite time)
Note
•
Avoid setting 1–50 for any of the values.
Default Value
60,500,440
Configuration File Reference
4.6.6 Tone Settings
Document Version: 2017-07
Administrator Guide