10. Remote Control Operating Instructions
10.1 Wired remote control
CZ-RT1
Name and function of each part
REMOTE
The OFF/ON button cannot be used.
LOCAL
All wired remote control buttons can be used.
Timer/time setting display
Check display
Fan Speed display
Operation mode selection display
FILTER RESET display
Appear after the cumulative running time reaches
approximately 2,500 hours of operation.
Temperature setting display (16°C – 31°C)
Airflow direction setting display
OFF/ON button
Used to start and stop the operation.
FAN SPEED button
Used to select the fan speed of HI, MED, LO or
AUTO.
MODE button
Used to select operation mode of AUTO, HEAT,
FAN, COOL or DRY.
TEMP (UP/DOWN) button
Use to select the desired temperature.
AIR SWING (AUTO/MANUAL) button
Not applicable for Hide Away models.
FILTER RESET button
Press to reset the “FILTER RESET” display after washing the filter.
TEST RUN button*
VENTILATION button*
ECONOMY button
Function not available for this model.
ODOUR WASH button
Function not available for this model.
CHECK button
Press this button if the check display is flashing.
TIMER/CLOCK SET button
Use to set the timer operation and the current time.
OPERATION Indicator
Light ON when the unit in operation.
NOTES
z
Buttons with * mark are not needed for normal operation. If one of these buttons is pressed by mistake, press the same button once again to
cancel the operation.
z
When the power resumed after power failure, by default the unit will restart automatically with all previous setting preserved by the memory
function under AUTO RESTART function.
Summary of Contents for S-32NA1E5
Page 4: ...4 23 6 Heating 430 24 Exploded View and Replacement Parts List451 24 1 Indoor Unit 451 ...
Page 12: ...12 ...
Page 40: ...40 4 1 2 S 56KA1E5 S 63KA1E5 S 71KA1E5 ...
Page 42: ...42 4 3 95 x 95 Cassette Type Indoor Unit 4 3 1 S 63UA1E5 S 71UA1E5 S 90UA1E5 ...
Page 44: ...44 4 5 Low Static Pressure Hide Away Type Indoor Unit 4 5 1 S 45MA1E5 S 56MA1E5 ...
Page 45: ...45 4 5 2 S 63MA1E5 S 71MA1E5 S 90MA1E5 ...
Page 51: ...51 7 Wiring Connection Diagram 7 1 Wall Mounted Type Indoor Unit KA1E5 Series ...
Page 52: ...52 7 2 60 x 60 Cassette Type Indoor Unit YA1E5 Series ...
Page 53: ...53 7 3 95 x 95 Cassette Type Indoor Unit UA1E5 Series ...
Page 54: ...54 7 4 Slim Hide Away Type Indoor Unit NA1E5 Series ...
Page 55: ...55 7 5 Low Static Pressure Hide Away Type Indoor Unit MA1E5 Series ...
Page 56: ...56 7 6 Outdoor Unit LA1E5 Series ...
Page 57: ...57 8 Electronic Circuit Diagram 8 1 Wall Mounted Type Indoor Unit KA1E5 Series ...
Page 58: ...58 ...
Page 59: ...59 8 2 60 x 60 Cassette Type Indoor Unit YA1E5 Series ...
Page 60: ...60 ...
Page 61: ...61 8 3 95 x 95 Cassette Type Indoor Unit UA1E5 Series ...
Page 62: ...62 ...
Page 63: ...63 8 4 Slim Hide Away Type Indoor Unit NA1E5 Series ...
Page 64: ...64 ...
Page 65: ...65 8 5 Low Static Pressure Hide Away Type Indoor Unit MA1E5 Series ...
Page 66: ...66 ...
Page 67: ...67 8 6 Outdoor Unit LA1E5 Series ...
Page 68: ...68 ...
Page 70: ...70 9 1 3 Receiver PCB CN DISP 9 1 4 Error Code Display PCB CN CODE ...
Page 74: ...74 9 6 Outdoor Unit LA1E5 Series 9 6 1 Main PCB ...
Page 76: ...76 9 6 3 Capacitor PCB DCN IN DCN OUT DCP IN DCP OUT ...
Page 195: ...195 ...
Page 201: ...201 ...