o
AC fan motor Manual fan speed and Auto fan speed depends on indoor heat exchanger temperature.
Stop
Reduced
Remote control
setting
Min Me
57
o
C
53
o
C
32
o
C
29
o
C
26
o
C
29
o
C
Stop
29
o
C
26
o
C
36
o
C
33
o
C
Hi
Indoor heat exchanger temperature
Indoor heat exchanger temperature
Reduced
o
AC Fan motor control during Thermostat OFF and Compressor OFF.
o
Temperature sampling during thermostat OFF, compressor ON and temperature between indoor intake
temperature and setting temperature is below 30°C.
Thermostat
ON
Sampling
signal from
outdoor unit
Indoor fan
Compressor
ON
OFF
OFF
ON
Remote controller
fan speed setting
DC fan motor: SLo
AC fan motor: Lo
DC fan motor: SLo
AC fan motor: Lo
20s
Sampling time
120s
240s
240s
120s
240s
120s
60
Ducted (D4)
60
Ducted (D3)
75
95x95 Cassette
75
60x60 Cassette
75
Wall mounted
Sampling time (s)
Model
60
Ducted (D4)
60
Ducted (D3)
75
95x95 Cassette
75
60x60 Cassette
75
Wall mounted
Sampling time (s)
Model
Summary of Contents for S-32NA1E5
Page 4: ...4 23 6 Heating 430 24 Exploded View and Replacement Parts List451 24 1 Indoor Unit 451 ...
Page 12: ...12 ...
Page 40: ...40 4 1 2 S 56KA1E5 S 63KA1E5 S 71KA1E5 ...
Page 42: ...42 4 3 95 x 95 Cassette Type Indoor Unit 4 3 1 S 63UA1E5 S 71UA1E5 S 90UA1E5 ...
Page 44: ...44 4 5 Low Static Pressure Hide Away Type Indoor Unit 4 5 1 S 45MA1E5 S 56MA1E5 ...
Page 45: ...45 4 5 2 S 63MA1E5 S 71MA1E5 S 90MA1E5 ...
Page 51: ...51 7 Wiring Connection Diagram 7 1 Wall Mounted Type Indoor Unit KA1E5 Series ...
Page 52: ...52 7 2 60 x 60 Cassette Type Indoor Unit YA1E5 Series ...
Page 53: ...53 7 3 95 x 95 Cassette Type Indoor Unit UA1E5 Series ...
Page 54: ...54 7 4 Slim Hide Away Type Indoor Unit NA1E5 Series ...
Page 55: ...55 7 5 Low Static Pressure Hide Away Type Indoor Unit MA1E5 Series ...
Page 56: ...56 7 6 Outdoor Unit LA1E5 Series ...
Page 57: ...57 8 Electronic Circuit Diagram 8 1 Wall Mounted Type Indoor Unit KA1E5 Series ...
Page 58: ...58 ...
Page 59: ...59 8 2 60 x 60 Cassette Type Indoor Unit YA1E5 Series ...
Page 60: ...60 ...
Page 61: ...61 8 3 95 x 95 Cassette Type Indoor Unit UA1E5 Series ...
Page 62: ...62 ...
Page 63: ...63 8 4 Slim Hide Away Type Indoor Unit NA1E5 Series ...
Page 64: ...64 ...
Page 65: ...65 8 5 Low Static Pressure Hide Away Type Indoor Unit MA1E5 Series ...
Page 66: ...66 ...
Page 67: ...67 8 6 Outdoor Unit LA1E5 Series ...
Page 68: ...68 ...
Page 70: ...70 9 1 3 Receiver PCB CN DISP 9 1 4 Error Code Display PCB CN CODE ...
Page 74: ...74 9 6 Outdoor Unit LA1E5 Series 9 6 1 Main PCB ...
Page 76: ...76 9 6 3 Capacitor PCB DCN IN DCN OUT DCP IN DCP OUT ...
Page 195: ...195 ...
Page 201: ...201 ...