Page 1: ...K36A RECREATION VEHICLE AIR CONDITIONER Installation Manual ...

Page 2: ...ency of failure The principle of the manual is to provide technical instruction on top installed air conditioner assembly for the technicians before and after sales services Read and follow the instruction mentioned in the user manual carefully Moreover it also provides the installation guideline on matching air conditioner manufacturers ...

Page 3: ...n 3 2 Technical Preparation Before Installation 3 3 Air Conditioner Guarantee 4 4 Assembly Selection 4 5 Installation Assembly 5 6 Assembly test run 9 7 Operation 10 8 Maintenance 10 9 Troubleshooting 10 Table1 2 13 Appendix1 2 15 ...

Page 4: ...he damages on personnel and machine because of the higher pressure 8 Shut off the power supply when making repair preventing the fireworks due to short circuit 9 Must be carefully if it s necessary to drill holes on the van These holes might reduce the construction strength Or result electric shock and fireworks when the holes drilled on the wire 10 Keep your hands far away from rotating parts suc...

Page 5: ...s The warranty card must be filled out completely and send back to manufacturer for registration See the Appendix 1 attached 4 Assembly Selection 1 Selection K36A is suitable installed on trailing car or van In order to determine the suitability of the warranty and guarantee consistently effective when in stalled in commercial vehicles and industrial vehicles must be approved by the com pany s tec...

Page 6: ...oning Figure 1 The figure1 describes the installation position of the air conditioner on van roof and ceiling 1 Install the unit on the front part of the top van ensure the unit exhaust in outdoor un effect 2 Do not install the unit at the place where affecting the air return or exhaust Since it will affects the uniform of the temperature of inside van 3 The location should be open to the centerli...

Page 7: ...6 Figure 2 ...

Page 8: ...ocedures Note Cross the top van with crawl plate avoiding the damages on the protecting walls of top van Must drill one hole through the top van 352 352mm The holes are in the middle of the top van supporting the unit Preventing the hot air mixed into air return 5 The unit cable connection 1 Install the power supply of the unit on the right hands 352 352mm 2 Comply with local electric standards 3 ...

Page 9: ... the van Observe the deforming of the assembly seat Adjust the thickness of shock absorber rubber gasket for leveling 4 Observe the installation of the air return outlet from the carriage Seal the seat EVR joints of the top van ensuring no leakage from the top van Figure 4 7 Connection cable Figure 5 is the connection of power supply It is connected with insert and interior channel Connect the ada...

Page 10: ...1 Turn on the power 2 Select vent from the control board 3 Adjust the air speed to HI or LO check all buttons working properly 4 Select COOL and adjust air volume to HI COOL Turn the temperature regulator anticlockwise Note If the room temperature is lower than 20 C the temperature regulator will restrain the running of the compressor ...

Page 11: ...urn filter is visible For example the dark appearance shows the filter is clean while the gray appearance indicates the air return filter need to be washed Open the air return grille with screwdriver and take out the filter screen Clean it with suds and dry Put the filter into the right place 9 Troubleshooting 1 Compressor not refrigerating Troubles Possible reasons Solution No air after turning o...

Page 12: ...st screen or evaporator fin 2 Air conditioner channel blocked Clean the channel 3 Evaporator fan fuse broken or relay damaged Check and replace 4 Evaportator fan damaged Check and replace 6 Evaporator fan input too low Check air conditioner circuit and grounding 3 Air conditioner systems not running properly Troubles Possible reasons Solution HP too high LP too high 1 Refrigerant too much Discharg...

Page 13: ...r evaporator fin HP lower LP too high Compressor interior valve damaged Check and replace compressor HP higher LP too high 1 Extension valve temperature sensor packing failure Put the temperature sensor on The pipe and pack the sensor with isolation 2 Temperature sensor leakage Replace the extension valve ...

Page 14: ...13 Table 1 Customer Info Name Address P C Phone Purchase Date Model S N Install Purchase Place Address P C Phone ...

Page 15: ...ASE Power consumption 1430W Current 6 5A Refrigerant R410A 700g Evaporator air flower 650m3 h dimension L W H 1040 575 340mm Unit weight 45kg Refrigerating conditions Indoors dry ball 27 C wet ball 19 5 C Outdoors dry ball 35 C wet ball 27 C We keep the right on products changing without notification in advance ...

Page 16: ...gh speed 0 1 3 4 A 2 l ow speed 0__1 heat i ng 0__1 0__4 hi gh speed 0__2 sm al l er cool i ng 0__1 0__3 hi gher cool i ng 0__2 0__3 S R C yel l ow green yel l ow green red 1 5 EH FT1 whi t e KA2 KA2 red 2 5 orange 14 13 12 8 6 5 5 6 3 2 3 2 whi t e C FU 30A red K36A ELECTRI C CLRCUI T DI AG RAM SA M ai n swi t ch Tem p swi t ch ST Power rel ay KA Fuse FU EH El c Heat er O ver heat er prot ect er ...

Page 17: ... M C 2 KT Ti m e r el ay KT C ondenser f an FA N C M C om pr essor El c H eat er EH EM E vapor at or bl ow er H P Pr ot ect C apaci t ance C H P KA Pow er r el ay FU Fuse ST Tem p sw i t ch M ai n sw i t ch SA EH KA 2 4 L H C 1 KA 1 FU 30A H L 3 1 2 L FA N C M ...