206
1
2
3
4
Screws to secure case
1: Brown cord
2: Red cord
3: Orange cord
4: Yellow cord
Orange cord
Brown cord
Red cord
Yellow cord
Shown without the decorative panel
Mount
Connect to the round terminals of the short wires No.1~4. Install securely using a crimp-type device for round
terminals. The cords have positive and negative properties. On the outdoor unit’s terminal module, match and
connect (optional connection) to the terminal points 1 through 4 for the Cooling/Heating Selector section on the
terminal module.
Terminal module with optional connection on
the outdoor unit’s control panel
To the next system outdoor unit
Cooling/Heating
Selector
Forced
Stop
Demand
1: Brown cord
Connect to terminal point 1 on terminal
block
2: Red cord
Connect to terminal point 2 on terminal
block
3: Orange cord
Connect to terminal point 3 on terminal
block
4: Yellow cord
Connect to terminal point 4 on terminal
block
When connecting to the short wire, follow the diagram below and strip 8 to 10 mm of the wire’s end exposing the
base wire. After inserting it into the connector, securely crimp the connection so it does not disconnect.
Connector
Short wire
8 ~ 10 mm
Stripped segment
4. Connect the earth wire
Connect the earth wire to the screw on the bottom
side of the case.
5. Open the hole to the exterior and pull the
electrical wiring through.
There is a hole on the bottom of the case and on
the side of the case.
Only use the necessary hole and pull the wiring
through to the exterior.
Seal the hole to prevent small animals from
entering the unit.
6. Install the case.
Re-install the case that was removed by securing
it with the screws.
7. Install the decorative panel.
Install the decorative panel by clipping it in.
There is a specific direction to install the
decorative panel.
Summary of Contents for S-32NA1E5
Page 4: ...4 23 6 Heating 430 24 Exploded View and Replacement Parts List451 24 1 Indoor Unit 451 ...
Page 12: ...12 ...
Page 40: ...40 4 1 2 S 56KA1E5 S 63KA1E5 S 71KA1E5 ...
Page 42: ...42 4 3 95 x 95 Cassette Type Indoor Unit 4 3 1 S 63UA1E5 S 71UA1E5 S 90UA1E5 ...
Page 44: ...44 4 5 Low Static Pressure Hide Away Type Indoor Unit 4 5 1 S 45MA1E5 S 56MA1E5 ...
Page 45: ...45 4 5 2 S 63MA1E5 S 71MA1E5 S 90MA1E5 ...
Page 51: ...51 7 Wiring Connection Diagram 7 1 Wall Mounted Type Indoor Unit KA1E5 Series ...
Page 52: ...52 7 2 60 x 60 Cassette Type Indoor Unit YA1E5 Series ...
Page 53: ...53 7 3 95 x 95 Cassette Type Indoor Unit UA1E5 Series ...
Page 54: ...54 7 4 Slim Hide Away Type Indoor Unit NA1E5 Series ...
Page 55: ...55 7 5 Low Static Pressure Hide Away Type Indoor Unit MA1E5 Series ...
Page 56: ...56 7 6 Outdoor Unit LA1E5 Series ...
Page 57: ...57 8 Electronic Circuit Diagram 8 1 Wall Mounted Type Indoor Unit KA1E5 Series ...
Page 58: ...58 ...
Page 59: ...59 8 2 60 x 60 Cassette Type Indoor Unit YA1E5 Series ...
Page 60: ...60 ...
Page 61: ...61 8 3 95 x 95 Cassette Type Indoor Unit UA1E5 Series ...
Page 62: ...62 ...
Page 63: ...63 8 4 Slim Hide Away Type Indoor Unit NA1E5 Series ...
Page 64: ...64 ...
Page 65: ...65 8 5 Low Static Pressure Hide Away Type Indoor Unit MA1E5 Series ...
Page 66: ...66 ...
Page 67: ...67 8 6 Outdoor Unit LA1E5 Series ...
Page 68: ...68 ...
Page 70: ...70 9 1 3 Receiver PCB CN DISP 9 1 4 Error Code Display PCB CN CODE ...
Page 74: ...74 9 6 Outdoor Unit LA1E5 Series 9 6 1 Main PCB ...
Page 76: ...76 9 6 3 Capacitor PCB DCN IN DCN OUT DCP IN DCP OUT ...
Page 195: ...195 ...
Page 201: ...201 ...