100 - ENGLISH
Technical Information
Using the PJLink protocol
The network function of the projector supports PJLink class 1, and the PJLink protocol can be used to perform projector setting
and projector status query operations from a computer.
Control commands
The following table lists the PJLink protocol commands that can be used to control the projector.
f
x characters in tables are non-specific characters.
Command
Control details
Parameter / return string
Remark
POWR
Power supply control
0
1
Standby
Power on
POWR ?
Power supply status
query
0
1
2
3
Standby
Power on
Cool-down in progress
Warm-up in progress
INPT
Input selection
11
Computer 1
12
Computer 2
21
Video
INPT ?
Input selection query
22
S-video
23
Component
31
HDMI
41
Memory Viewer
51
USB Display
52
Network
AVMT
AV mute/Mute control
10
Video mute off
11
Video mute on
20
Audio mute off
AVMT ?
AV mute/Mute status
query
21
Audio mute on
30
AV mute off
31
AV mute on
ERST ?
Error status query
××××××
1st byte Fixed at 0
f
0 = No error known
f
1 = Warning
f
2 = Error
2nd byte Indicates lamp errors,
range 0 – 2
3rd byte Indicates temperature
errors, range 0 – 2
4th byte Fixed at 0
5th byte Fixed at 0
6th byte Fixed at 0
LAMP ?
Lamp status query
xxxxx x
1st digits (1 – 5 digits) : Lamp cumulative operating time
2nd digit : 0 = Lamp off, 1 = Lamp on
INST ?
Input selection list
query
11 12 21 22 23 31 41 51 52
NAME ?
Projector name query PROJECTOR
INF1 ?
Manufacturer name
query
Panasonic
Returns manufacturer name.
INF2 ?
Model name query
PT-TW370, PT-TX430,
PT-TX340
Returns model name.
INF0 ?
Other information
query
×××××
Returns information such as version number.
CLSS ?
Class information
query
1
Returns class for PJLink.
PJLink security authentication
The password used for PJLink is the same as that of the password set for web control.
When using the projector without security authentication, do not set a password for web control function.
f
For specifications related to PJLink, refer to the website of Japan Business Machine and Information System Industries
Association.
URL http://pjlink.jbmia.or.jp/english/
Chapter 7 Appendix - Technical Information