Chapter 4
Settings — [PROJECTOR SETUP] menu
176 - ENGLISH
[DATA CLONING]
Perform the operations of the data cloning function. Data such as the settings and adjustment values of the
projector can be copied to multiple projectors via LAN.
For details of operation, refer to “Using the data cloning function” (
x
page 215).
[SAVE ALL USER DATA]
Save the various setting values as a backup in the built-in memory of the projector.
1) Press
as
to select [SAVE ALL USER DATA].
2) Press the <ENTER> button.
f
The
[SECURITY PASSWORD]
screen is displayed.
3) Enter a security password and press the <ENTER> button.
f
The confirmation screen is displayed.
4) Press
qw
to select [OK], and press the <ENTER> button.
f
[PROGRESS] is displayed while saving data.
Note
f
Data set from the computer application is not included in [ALL USER DATA].
f
The data saved by executing [SAVE ALL USER DATA] is not deleted even if the [PROJECTOR SETUP] menu
→
[INITIALIZE]
→
[ALL
USER DATA] is executed.
[LOAD ALL USER DATA]
Load the various setting values saved as a backup in the built-in memory of the projector.
1) Press
as
to select [LOAD ALL USER DATA].
2) Press the <ENTER> button.
f
The
[SECURITY PASSWORD]
screen is displayed.
3) Enter a security password and press the <ENTER> button.
f
The confirmation screen is displayed.
4) Press
qw
to select [OK], and press the <ENTER> button.
Note
f
The projector enters the standby mode to reflect the setting values when [LOAD ALL USER DATA] is executed.
f
Data registered from a computer is not included in [ALL USER DATA].
[INITIALIZE]
Return various setting values to their factory default settings.
1) Press
as
to select [INITIALIZE].
2) Press the <ENTER> button.
f
The
[SECURITY PASSWORD]
screen is displayed.
3) Enter a security password and press the <ENTER> button.
f
The
[INITIALIZE]
screen is displayed.
4) Press
as
to select an item to initialize.
[ALL USER DATA]
Returns all setting values including [REGISTERED SIGNAL], [NETWORK/E-MAIL], [LOGO IMAGE],
and [UNIFORMITY] to the factory default settings.
The projector enters the standby mode to reflect the setting values.
[REGISTERED SIGNAL]
Deletes all the setting values saved for each input signal.
To delete only a part of a registered signal, perform the procedure described in “Deleting the
registered signal” (
x
page 181).
[NETWORK/E-MAIL]
Returns [NETWORK SETUP] and [E-mail set up] to factory default settings.
[LOGO IMAGE]
Deletes the image registered in [USER LOGO].
[UNIFORMITY]
Returns [UNIFORMITY] to factory default setting.