The following describes how to use several commands on this screen.
-------------------------------------------------------------------------------------------------------------------------------------------
Note:
The manual settings for the upper-limit value of power supply is needed to per
-
form in the range from 15,600 to 30,000mW if more than 15.4W is required, and the
power is supplied to 2-Event Physical Layer Classification or the PoE power receiver,
which is non-compliant with IEEE802.3at that does not support Data Link Layer
Classification.
-------------------------------------------------------------------------------------------------------------------------------------------
N
Displays the next page.
Press N (command) to display the next page.
P
Displays the previous page.
Press P to display the previous page.
S
Configures if the power supply can operate (or is possible to work).
1. Press S (command) and then the appearance of the command prompt becomes "Enter
port-number>" Enter the port-number to change. (Enter 0 when changing all the ports,
simultaneously.)
2. As the appearance of the command prompt becomes “Up or Down PoE port admin
status (U/D)>”, press U to configure Up, and D for Down.
I
Configures the priority of the power supply.
1. Press I (command) and then the appearance of the command prompt becomes "Enter
port-number>". Enter the port-number to be changed. (Enter 0 when changing all the
ports, simultaneously.)
2. As the appearance of the command prompt becomes “Enter the selection>”, press 1
to set the priority to Critical, 2 to High, and 3 to Low.
L
Configures the upper-limit of power supply.
1. Press L (command) and then the appearance of the command prompt becomes "Enter
port-number>".
2. Enter the port-number to be changed. (Enter 0 when changing all the ports,
simultaneously.)
3. The appearance of the command prompt becomes "Enter limit mode for port # (A/M)>".
Then press A to configure the upper-limit automatically, and M to configure manually.
4. Press M, and then the appearance of the command prompt becomes "Enter the power
limit>".
5. Enter the upper-limit to configure in the range from 3,000 to 30,000mW (200mW: unit)
After entering is complete, the configuration becomes changed, and then the top part of
the display becomes changed automatically. The case is that the upper configuration of the
power-supply amount is set to Auto. After detecting the terminal equipment, the
combination of Layer and Class configures the following values as the limit-value of ports,
automatically. If the upper configuration of the power supply is set to Auto, the class-value
shown (after detecting the power-supply terminal) configures the port-limit value,
automatically.
Q
Returns to the top menu.
Class
Layer
1
2
0
15400
14000
1
4000
4000
2
7000
6800
3
15400
14000
4
15400
30000