Network Firmware Update Tool (LAN)
Page 6
3. Preparing the Firmware Update
3.1 Preparing the Unit to Accept the Firmware Code
3.1.1
For DX-600 / DX-800 (v1.31 or higher)
1.
If the device password is changed (Remote Password) from the default value (blank = 0000), it is
not possible to program the firmware code. In this case, enter the password in advance to the
Default Password in the Configuration dialog box, or enter the password at each communication.
2.
Make sure the device is not in an operating condition (copying or printing etc...).
Note:
It is recommended to update the firmware at night due to lower activity of the device.
3.1.2
For other models
1.
If the device password (
Service Mode F7-01
= Key Operator ID Code, or Operation Password) is
changed from the default value (0000 or 000), it is not possible to program the firmware code. In
this case, enter the password in advance to the Default Password in the Configuration dialog box,
or enter the password at each communication.
For the 3-digit Key Operator Password devices, only the first three digits “000” of the default value
are singled out of the 4-digit “0000” value.
2.
Make sure the device is not in an operating condition (copying or printing etc...).
Note:
It is recommended to update the firmware at night due to lower activity of the device.
3.2 Preparing the Firmware Code
Copy the firmware Code file(s) to the following folder.
C:\Panasonic\Panasonic-FUP\Data
Note:
The Archive File extracts the Firmware Code Files automatically into the designated folder.
(ex. DP-2310_PU_030327.exe)
Summary of Contents for Panafax UF-8100
Page 9: ...Table of Contents 9 Schematic Diagram 303 10 1 General Circuit Diagram 303 ...
Page 122: ...122 UF 7000 8000 APR 2007 Ver 2 1 UF 7100 8100 Sensor and Switch Location ...
Page 304: ...304 APR 2007 Ver 2 1 UF 7000 8000 UF 7100 8100 memo ...
Page 320: ...memo ...
Page 336: ...memo ...
Page 373: ...memo ...
Page 374: ...DZZSM00287 ...