SX-DCT00221 -
3-
Panasonic Corporation
4.3
Insulation resistance
More than DC500 V 20 M
Ω
(Between power supply and frame)
4.4
Isolation voltage
Between power supply and earth
AC1500 V 1 minute
4.5
Dimensional Outline drawing
200 W, 400 W, 750 W
5. Function of terminal
5.1 Connector for power input (POWER)
Molex 5569-10A-1210 or equivalent
Pin No.
Terminal
symbol
Terminal
name
Description of function
3
B
for external
regenerative
resistor
Connect for external regenerative resister in case.
DV0P2890 for 100V
DV0PM20068 for 200V
5
P
6
L3
Power input
Connect the terminal to commercial power supply con-
forming to voltage specification. In case of single-phase
connect L1 and L2.
8
L2
10
L1
1,2,4,7,
9
(NC)
-
Do not connect anything.
5.2 Grounding terminal (
)
Terminal for
grounding the amplifier.(M4
×
2pieces)
Fasten only one wire to one terminal.
Fasten torque:0.5-1.0N
・
m
※
1 Trip means that a protection circuit operates and stops.
※
Install the top and bottom properly, and provide a space of around 10 cm for heat dissipation
When dealing with the product, please take measure against static electricity.
Power-LED(PWR)
Green:Power ON
Alarm-LED(ALM)
Red:Trip
※
1
Connector for control
signals
(I/O)
Connector for
communications (SER)
Terminal for
power input
(POWER)
Connector for motor
connection (MOTOR)
UP
Grounding
terminal
(
)