SX-DCT00221 -
54-
Panasonic Corporation
8103h: Amplifier status
●
$R: Status reading request command
Received data (Host
→
Amplifier)
Amplifier ID Host ID Command Data number Data value
・
Enter request for sending after execution of this command, the amplifier status is answered.
・
Set ‘0000’ in data value.
●
#R: Status response command
Transmission data (Amplifier
→
Host)
Host ID Amplifier ID Command Data number Data value
・
When the amplifier receives request for sending after normal completion of status reading request com-
mand,
the amplifier answers status value.
●
#C: Data updating request command
Transmission data (Amplifier
→
Host)
Host ID Amplifier ID Command Data number Data value
・
The amplifier saves the status in executing request for sending, and makes the response above when
the
status in receiving the next request for sending has changed. Read data is the same as in execution of
data number 8103.
[Detail of status]
Bit 3
Bit 2
Bit 1
Bit 0
D1
0
0
0
0
D2
0
0
0
0
D3
Torque under re-
striction
Overload detection
0
0
D4
Homing completion
In-motion
In-position
Trip output
Detail
above is converted into hexadecimal and represented in ASCII code.
e.g.) Data value = 30h 30h 30h 41h = ‘000A’ = It is shown that it is running.
SOH
STX
$
R
8
1
0
3
0
0
0
0
ETX BCC
SOH
STX
#
R
8
1
0
3
D1 D2 D3 D4 ETX BCC
SOH
STX
#
C
8
1
0
3
D1 D2 D3 D4 ETX BCC