SX-DCT00221 -
43-
Panasonic Corporation
13-5. List of data number related to communications
(1)
Communication parameter
:
Address
Pr No.
*
1
Parameter
name
Data value
Default
Note
8060h
60
RS485 device num-
ber
80h – 9Fh
0081h
*
9
*
10
8061h
61
RS485 communication
speed
0: 2400 bps, 1: 4800 bps, 2: 9600 bps
0002h
*
9
8062h
62
RS485 com-
munication
standard
Set the communication standard of RS485
communication.
0: 8 bits, no parity, stop bit 1
1: 8 bits, no parity, stop bit 2
2: 8 bits, odd number parity, stop bit 1
3: 8 bits, odd number parity, stop bit 2
4: 8 bits, even number parity, stop bit 1
5: 8 bits, even number parity, stop bit 2
6: 7 bits, no parity, stop bit 1
7: 7 bits, no parity, stop bit 2
8: 7 bits, odd number parity, stop bit 1
9: 7 bits, odd number parity, stop bit 2
10: 7 bits, even number parity, stop bit 1
11: 7 bits, even number parity, stop bit 2
0004h
*
9
8063h
63
RS485 commu-
nication re-
sponse time
10 – 1000 (ms)
000Ah
*
9
8064h
64
RS485 retry
times of commu-
nication
0 – 8: Retry count, 9: No retry
0009h
*
9
8065h
65
RS485 protocol
timeout
1 – 255 (s)
0002h
*
9
*
1) Pr No. shows the parameter number in Digital keypad.
*
9) Change becomes effective, when power is turned off once and turned on again after 10 seconds.
*
10) When the device number is set to 80h (128), change of parameter and request for status are ignored, therefore set
to 81h (129) - 9Fh (159) normally.