№
SX-DCT00221 -
38-
Panasonic Corporation
12. Conformance to overseas standard
EC Directives
This brushless amplifier realizes compliance with the relevant standard of low voltage directive in order to facilitate
conformity to the EC directive of the machinery and equipment to be incorporated.
EMC Directives
Brushless amplifiers are not intended for general home use or connection to low-voltage public communication
lines. Connecting to such a circuit may cause radio frequency interference.
This brushless amplifier decides the model such as installation and wiring, and it conforms to the relevant stand-
ard of the EMC directive in that model. Wiring conditions, grounding conditions, etc. may not be the same as
those of the model in the state where it is incorporated in actual machinery / equipment. Therefore, as for compli-
ance with the EMC directive in machinery / equipment, it is necessary to measure with the final machinery /
equipment incorporating this product (especially Radiated Emissions, Conducted Emissions etc.).
Applicable standard
*
1
SCCR: 5,000 rms symmetrical amperes, 240 Volts maximum.
Integral solid state short circuit protection does not provide branch circuit protection. Branch circuit protection must be
provided in accordance with the National Electrical Code and any additional local codes.
(These devices are not provided with motor over-temperature sensing.)
*
2
Precautionary note written in Korean
A
급 기기
(
업무용 방송통신기자재
)
이 기기는 업무용
(A
급
)
전자파적합기기로서 판매자
또는 사용자는 이 점을 주의하시기 바라며
,
가정외의
지역에서 사용하는 것을 목적으로 합니다
.
(
대상기종
: Brushless Amplifier )
(English translation)
Distributors and users must understand that this product meet the electromagnetic compatibility requirements and
is designed for industrial use (class A). Do not use the product in a residential area.
(Application product: Brushless Amplifier)
Applicable standard
Installation
condition
File No.
UL
UL508C
Standard for electric converter equipment
Class
Ⅰ
equipment
Pollution
degree 2
*
1
E164620
CSA
C22.2 No.14-10
Adjustable speed drives
CE
EN61800-5-1
EN61800-3
EN55011
EN61000-6-2
Adjustable speed electrical power drive systems
(
Safety requirements— Electrical, thermal and energy)
Adjustable speed electrical power drive systems
( EMC requirements and specific test methods)
Radio interference wave characteristics of industrial, scientific,
and medical high-frequency equipment
Standards for immunity in industrial environment
Overvoltage
category
Ⅱ
Class1
equipment
Pollution de-
gree 2
Group
1,
Class A and
Category
C3
2nd environ-
ment
-
KC
Radio Waves Act
(South Korea)
*
2
Broadcasting and Communication Equipments
-
-