2-44
[Class 3] Verocity/ Torque/ Full-closed control
Parametr
No.
Title
Range
Default
Unit
Attribute
Related
Control Mode Detail
page
Class No.
A,B
-frame
C
-frame
D,E,F
-frame
INI RO
P S T F
3
00
Speed setup, Internal/External switching
0 to 3
0
−
P
S
T F
4-24
3
01
Speed command rotational direction
selection
0 to 1
0
−
P
S
T F
3
02
Input gain of speed command
10 to 2000
500
(r/min)/
V
P
S T
F
4-25
3
03
Reversal of speed command input
0 to 1
1
−
P
S
T F
3
04
1st speed of speed setup
−20000 to 20000
0
r/min
P
S
T F
4-26
3
05
2nd speed of speed setup
−20000 to 20000
0
r/min
P
S
T F
3
06
3rd speed of speed setup
−20000 to 20000
0
r/min
P
S
T F
3
07
4th speed of speed setup
−20000 to 20000
0
r/min
P
S
T F
3
08
5th speed of speed setup
−20000 to 20000
0
r/min
P
S
T F
3
09
6th speed of speed setup
−20000 to 20000
0
r/min
P
S
T F
3
10
7th speed of speed setup
−20000 to 20000
0
r/min
P
S
T F
3
11
8th speed of speed setup
−20000 to 20000
0
r/min
P
S
T F
3
12
Acceleration time setup
0 to 10000
0
ms/
(1000r/min)
P
S
T F
3
13
Deceleration time setup
0 to 10000
0
ms/
(1000r/min)
P
S
T F
3
14
Sigmoid acceleration/ deceleration time
setup
0 to 1000
0
ms
P
S
T F
4-27
3
15
Speed zero-clamp function selection
0 to 3
0
−
P
S T
F
3
16
Speed zero clamp level
10 to 20000
30
r/min
P
S T
F
3
17
Selection of torque command
0 to 2
0
−
P S
T
F
4-28
3
18
Torque command direction selection
0 to 1
0
−
P S
T
F
3
19
*
Input gain of torque command
10 to 100
30
0.1V/100%
P S
T
F
3
20
Input reversal of torque command
0 to 1
0
−
P S
T
F
3
21
Speed limit value 1
0 to 20000
0
r/min
P S
T
F
4-29
3
22
Speed limit value 2
0 to 20000
0
r/min
P S
T
F
3
23
External scale selection
0 to 2
0
−
P S T
F
3
24
Numerator of external scale division
0 to 2
20
0
−
P S T
F
4-30
3
25
Denominator of external scale division
1 to 2
20
10000
−
P S T
F
3
26
Reversal of direction of external scale
0 to 1
0
−
P S T
F
3
27
External scale Z phase disconnection
detection disable
0 to 1
0
−
P S T
F
3
28
Hybrid deviation excess setup
1 to 2
27
16000
Command
unit
P S T
F
4-31
3
29
Hybrid deviation clear setup
0 to 100
0
Revolution
P S T
F
* Definition of symbols under “Attribute” - INI: turning on of power supply is required, RO: read only
*
Definition of symbols under “Related mode” - P: position control, S: velocity control, T: torque control, F: full closed control
13. Setup of Parameter and Mode
List of Parameters
Caution
Note
The symbol “
*
” attached to a parameter No. indicates that the digits of setting unit will
change if the parameter is set by using the setup support software PANATERM.
Parameter describes of this page is P.4-24 to P.4-31.