4-32
Pr4.00
*
Title
SI1 input selection
Related
control mode
P S T F
Range
0 to 00FFFFFFh
Unit
—
Default
00828282h
(8553090)
Assign functions to SI1 inputs.
These parameters are presented in hexadecimals.
*
5
Hexadecimal presentation is followed by a specific control mode designation.
0 0 – – –
* *
h : position/full-closed control
0 0 – –
* *
– – h : velocity control
0 0
* *
– – – – h : torque control
Replace
* *
with the function number.
For the function number see the table below. Logical setup is also a function number.
Title
Symbol
Setup value
a-contact
b-contact
Invalid
−
00h
Do not setup.
Positive direction over-travel inhibition input
POT
01h
81h
Negative direction over-travel inhibition input
NOT
02h
82h
Servo-ON input
*
1
SRV-ON
03h
83h
Alarm clear input
A-CLR
04h
Do not setup.
Control mode switching input
*
2
C-MODE
05h
85h
Gain switching input
GAIN
06h
86h
Deviation counter clear input
*
3
CL
07h
Do not setup.
Command pulse inhibition input
*
4
INH
08h
88h
Torque limit switching input
TL-SEL
09h
89h
Damping control switching input 1
VS-SEL1
0Ah
8Ah
Damping control switching input 2
VS-SEL2
0Bh
8Bh
Electronic gear switching input 1
DIV1
0Ch
8Ch
Electronic gear switching input 2
DIV2
0Dh
8Dh
Selection 1 input of internal command speed
INTSPD1
0Eh
8Eh
Selection 2 input of internal command speed
INTSPD2
0Fh
8Fh
Selection 3 input of internal command speed
INTSPD3
10h
90h
Speed zero clamp input
ZEROSPD
11h
91h
Speed command sign input
VC-SIGN
12h
92h
Torque command sign input
TC-SIGN
13h
93h
Forced alarm input
E-STOP
14h
94h
Inertia ratio switching input
J-SEL
15h
95h
Caution
• Do not setup to a value other than that specified in the table.
• Do not assign specific function to 2 or more signals. Duplicated assignment will cause Err33.0 I/F input
multiple assignment error 1 or Err33.1 I/F input multiple assignment error 2.
*
1 Servo-on input signal (SRV-ON) must be used to enable servo-on.
*
2 When using control mode switching input (C-MODE), set the signal to all control modes. If the signal is
set to only 1 or 2 control modes, Err33.2 I/F input function number error 1 or Err33.3 I/F input function
number error 2 will be generated.
• The control input pin set to invalid state does not affect any operation.
• Function (servo-on input, alarm clear, etc.) to be used in multiple control modes must be assigned to
the same pin with correct logical arrangement. Incorrect setting will cause Err33.0 I/F input multiple
assignment error 1 or Err33.1 I/F input multiple assignment error 2.
*
3 Deviation counter clear input (CL) can be assigned only to SI7 input. Wrong assignment will cause
Err33.6 Counter clear assignment error.
*
4 Command pulse inhibit input (INH) can be assigned only to SI10 input. Wrong assignment will cause
Err33.7 Command pulse input inhibit input.
*
5 Note that the front panel indicates parameter value in decimal number.
4
1. Details of parameter
Setup
[Class 4] I/F monitor setting