71
3.
Reinstall the focus adjustment cover.
Tightening torque for the cover should be 0.3 N • m or less.
Reference
•
Focus adjustment range varies depending on models.
•
LP-430(T)U / LP-420S9(T)U / LP-410(T)U: Approx. ± 3 mm
•
LP-431(T)U / LP-421S9(T)U / LP-411(T)U / LP-V10U: Approx. ± 2 mm
•
LP-435(T)U / LP-425S9(T)U: Approx. ± 4 mm
•
LP-V15U: Approx. ± 7 mm
•
LP-W052U: Approx. ± 0.7 mm
•
The ruler is set to “0” at factory.
• Adjusting focus changes the marking field and spot diameter. In addition, the amount of the spot diameter difference
between the marking field center and the marking field end becomes large, which may cause uneven marking quality.
• The dual pointer is adjusted according to the distance from the work defined at the factory. When the work distance is
changed by the focus adjustment function, dual pointer does not move with this function, so it cannot be used as the
work distance guide. Refer to “Dual Pointer Function” (P.69).
ME-LP400V-OP-6
Summary of Contents for LP-V Series
Page 11: ...11 MEMO ME LP400V OP 6 ...
Page 32: ...32 1 Product Overview ME LP400V OP 6 ...
Page 58: ...2 Installation and Connection ME LP400V OP 6 ...
Page 77: ...3 Basic Operation Procedure ME LP400V OP 6 ...
Page 121: ...4 Description of Operation Screen ME LP400V OP 6 ...
Page 146: ...146 Symbol ME LP400V OP 6 ...
Page 271: ...271 MEMO ME LP400V OP 6 ...
Page 272: ...Maintenance ME LP400V OP 6 ...
Page 291: ...Troubleshooting ME LP400V OP 6 ...
Page 308: ...Appendix ME LP400V OP 6 ...
Page 328: ...Index ME LP400V OP 6 ...
Page 333: ...No 9000 0062 14V ...
Page 334: ... Panasonic Industrial Devices SUNX Co Ltd 2003 2018 July 2018 9000 0062 14V ...