229
Mark “123456” with LP-431/LP-421/LP-411/LP-W052 (Marking field: 55mm x 55mm)
First, set the character string to be marked on the character setting screen.
Set the character string with its width of the character string per one line should be around 36mm. (except the last area
number)
1st line: 123 (character string width: 42mm)
2nd line: 456 (character string width: 42mm)
Next, set the marking condition of each line on the marking condition setting screen. The setting should be:
“Condition No. 1, Area No. 0” for the 1st line
“Condition No. 2, Area No. 1” for the 2nd line
4 5 6
1 2 3
Make sure that the width of the character string
should match with or go over the projection line on
the marking image screen.
Calculate the start position of “4”, which is the head
character of Area No. 1 on the X coordinate using the
following formula:
Formula: -27.5 + (character string width on the 1st line
-55mm x 2/3)
In this sample, the character string width on the 1st line is
42mm, and therefore the calculation will be:
Starting position of the head character on the X coordinate
= -27.5 + (42 - 55 x 2/3) ≈ -22
Moving direction: LEFT
Downstream
Upstream
Moving direction: LEFT
Downstream
Upstream
Character condition of “123” on the 1st line
Character condition of “456” on the 2nd line
Character condition No. 1
Character Height
Character Width
Character Interval
: 12
: 12
: 14
X Position
Y Position
Area No.
: -27.5
: 0
: 0
Character condition No. 2
Character Height
Character Width
Character Interval
: 12
: 12
: 14
X Position
Y Position
Area No.
: -22
: 0
: 1
Reference
•
Specify the character setting so that the last character in the character string should match with or go over the projection
line on the marking image screen. The projection line on the marking image screen indicates x 2/3 of marking field (starting
of the next marking field). (There may be the cases that the characters set outside of the guide line (the characters in the
upstream of moving direction) cannot be marked during low-speed operation.)
ME-LP400V-OP-6
Summary of Contents for LP-V Series
Page 11: ...11 MEMO ME LP400V OP 6 ...
Page 32: ...32 1 Product Overview ME LP400V OP 6 ...
Page 58: ...2 Installation and Connection ME LP400V OP 6 ...
Page 77: ...3 Basic Operation Procedure ME LP400V OP 6 ...
Page 121: ...4 Description of Operation Screen ME LP400V OP 6 ...
Page 146: ...146 Symbol ME LP400V OP 6 ...
Page 271: ...271 MEMO ME LP400V OP 6 ...
Page 272: ...Maintenance ME LP400V OP 6 ...
Page 291: ...Troubleshooting ME LP400V OP 6 ...
Page 308: ...Appendix ME LP400V OP 6 ...
Page 328: ...Index ME LP400V OP 6 ...
Page 333: ...No 9000 0062 14V ...
Page 334: ... Panasonic Industrial Devices SUNX Co Ltd 2003 2018 July 2018 9000 0062 14V ...