177
Description
9
Starting Position :
Specifies the start position of counter in the Step & Repeat patterns.
Select the position between [Upper L] or [Upper R].
10 Direction :
When the Step & Repeat counter is used, select the direction of counting between horizontal and vertical.
Reference
•
This direction setting is applied only to the counting direction, but not to the marking order.
•
If the counter function is set with Step & Repeat, the counting order becomes as follows.
Ex. Step & Repeat of 3 rows and 3 columns with counter update at each step. (“1” is the base position.) :
1
4
7
2
5
8
3
6
9
3
6
9
2
5
8
1
4
7
1
2
3
4
5
6
7
8
9
7
8
9
4
5
6
1
2
3
Starting Position: Upper L
Starting Position: Upper R
Starting Position: Upper L
Starting Position: Upper R
Marking Direction: horizontal Marking Direction: horizontal
Marking Direction: vertical
Marking Direction: vertical
Step & Repeat setting sample
Setting parameter:
•
Character: ABC
•
Number of Rows: 4
•
Number of Columns: 3
•
Row Step: 5 mm
•
Column Step: 10 mm
1st
2nd
3rd
4th
1st
2nd
3rd
ABC
ABC
ABC
ABC
ABC
ABC
ABC
ABC
ABC
ABC
ABC
ABC
Column Step: 10 mm
Row Step: 5 mm
Number of Columns: 3
Number of
Rows: 4
Reference
• The settings of “Common Condition” in “General Condition” are reflected after the settings in “Step & Repeat” are
applied.
ME-LP400V-OP-6
Summary of Contents for LP-V Series
Page 11: ...11 MEMO ME LP400V OP 6 ...
Page 32: ...32 1 Product Overview ME LP400V OP 6 ...
Page 58: ...2 Installation and Connection ME LP400V OP 6 ...
Page 77: ...3 Basic Operation Procedure ME LP400V OP 6 ...
Page 121: ...4 Description of Operation Screen ME LP400V OP 6 ...
Page 146: ...146 Symbol ME LP400V OP 6 ...
Page 271: ...271 MEMO ME LP400V OP 6 ...
Page 272: ...Maintenance ME LP400V OP 6 ...
Page 291: ...Troubleshooting ME LP400V OP 6 ...
Page 308: ...Appendix ME LP400V OP 6 ...
Page 328: ...Index ME LP400V OP 6 ...
Page 333: ...No 9000 0062 14V ...
Page 334: ... Panasonic Industrial Devices SUNX Co Ltd 2003 2018 July 2018 9000 0062 14V ...