Page 1-39
REGULAR
MAINTENANCE
1
Check Every 140 Hours (Once a Week)
7
. Press the
MODE
(mode) key of vacuum
sensor once.
∗
The sensor displays “P-1.” (The setting value
or “P-1” appears in turn.)
8
. Press either
or
key of vacuum
sensor, so that the vacuum sensor
displays the following value.
∗
Head A is PA0 –29
Head B is PB0 –29
Head C is PC0 –29
e.g.) As for the head A, press
or
key, so
that – 280 – 29 = –309 appears when PA0
recorded at the procedure 5. is – 280.
9
. Press the
MODE
(mode) key of vacuum
sensor once.
∗
The sensor displays “P-2.”
10
. Press either
or
key of vacuum
sensor, so that the vacuum sensor
displays the following value.
∗
Head A is PA0 –30
Head B is PB0 –30
Head C is PC0 –30
e.g.) As for the head A, press
or
key, so
that – 280 – 30 = – 310 appears when PA0
recorded at the procedure 5. is – 280.
To the next page
443C-357E
DP3-80
OUT 1
OUT 2
0-ADJ
SUNX
MODE
DP3-80
OUT 1
OUT 2
0-ADJ
SUNX
MODE
DP3-80
OUT 1
OUT 2
0-ADJ
SUNX
MODE
DP3-80
OUT 1
OUT 2
0-ADJ
SUNX
MODE
443C-358E
DP3-80
OUT 1
OUT 2
0-ADJ
SUNX
MODE
DP3-80
OUT 1
OUT 2
0-ADJ
SUNX
MODE
443C-359E
DP3-80
OUT 1
OUT 2
0-ADJ
SUNX
MODE
DP3-80
OUT 1
OUT 2
0-ADJ
SUNX
MODE
443C-360E
493C-E-MMA01-A05-00