Page 1-76
Check Every 3000 Hours (Once Per Half a Year)
6.
Apply grease to the grease applying
face of the dust seal B with fingers.
[Oil: MOLYKOTE EM-50L]
7.
Turn on the servo switch.
8.
Press
UNLOCK
and UX .
• After the Y-axis of X-Y unit moves to the origin,
the detection head of X-axis goes and returns
at full stroke, spreading the grease to the
whole seal of X-axis linear encoder.
9.
Press
UNLOCK
and UY .
• After the X-axis of X-Y unit moves to the origin,
the detection head of Y-axis goes and returns
at full stroke, spreading the grease to the
whole seal of Y-axis linear encoder.
10.
Turn off the servo switch.
OFF ( ) ON ( )
SERVO
OFF ( ) ON ( )
SERVO
493C-E-MMA01-A09-00
1
2
4
3
C B A
X-axis linear encoder
Front side
Y-axis linear encoder
Front side
1
2
4
3
C B A
433C-102E
433C-103E
433C-101E