Page 1-28
Check Every 140 Hours (Every Week)
2.
Removing the nozzle
Move the head unit to the feeder bay 4 in the “Maintenance mode,” and remove the nozzle.
1.
Turn on the servo switch.
2.
Press
UNLOCK
and .
• The head unit moves to the feeder bay 4.
3.
Turn off the servo switch.
4.
Put boxes under the head unit.
∗
It needs to prepare for falling down of tools,
clamp of nozzle holder, or screws inside of
machine.
Front side
OFF ( ) ON ( )
SERVO
OFF ( ) ON ( )
SERVO
Move to
feeder bay 4
493C-E-MMA01-A05-03
1
2
4
3
C B A
433C-056P
433C-085E