2.7
Extension Programming
256
General Programming
[622]
Incoming Call Display
Description
Allows you to choose between three display types when an incoming call is received.
"Caller" means the incoming caller's telephone number and name are displayed. "CO Line"
means the CO line number and CO line name assigned in the programme [421]
Name Assignment are displayed. "DDI" means the called party's DDI number and extension
name are displayed.
Selection
•
Jack number:
KX-TD816 – 01 through 16,
KX-TD1232 – 01 through 64,
( =all jacks)
•
Display Types:
Caller / CO Line / DDI
Default
All jacks – Caller
Programming
1.
Enter 622.
Display: Incoming Display
2.
Press NEXT.
Display: Jack NO ?
3.
Enter a jack number.
To enter jack number 01, you can also press NEXT.
Display example: #01:Caller
4.
Keep pressing SELECT until the desired selection is displayed.
5.
Press STORE.
6.
To programme another jack, press NEXT or PREV, or SELECT and the desired jack
number.
7.
Repeat steps 4 through 6.
8.
Press END.
Conditions
•
For the KX-TD1232, jack numbers 01 through 32 are for the Master System and 33 through
64 are for the Slave, if available.
Summary of Contents for KX-TD1232NE
Page 2: ...2 ...
Page 8: ...8 Table of Contents ...
Page 9: ...General Instructions 9 Section 1 General Instructions ...
Page 26: ...1 5 Example of Programming 26 General Instructions ...
Page 27: ...General Programming 27 Section 2 General Programming ...
Page 96: ...2 2 System Programming 96 GeneralProgramming Feature References Charge Fee Reference ...
Page 162: ...2 5 CO Line Programming 162 GeneralProgramming Feature References Intercept Routing ...
Page 171: ...2 5 CO Line Programming General Programming 171 Feature References Display Call Information ...
Page 208: ...2 6 COS Programming 208 GeneralProgramming Toll Restriction ...
Page 245: ...2 7 Extension Programming General Programming 245 Feature References Data Line Security ...
Page 297: ...DECT Programming 297 Section 3 DECT Programming ...
Page 324: ...3 1 DECT Programming 324 DECT Programming Feature References Department Codes ...
Page 335: ...3 1 DECT Programming DECT Programming 335 Display Call Information ...
Page 339: ...Default Values 339 Section 4 Default Values ...
Page 350: ...350 Default Values 682 Radio Information Data Clear Not applicable Program Default ...
Page 351: ...Default Values 351 ...