2.5
CO Line Programming
General Programming
155
2.5
CO Line Programming
[400]
CO Line Connection Assignment
Description
Used to identify the CO lines which are connected to the system. This prevents users from
originating a call to a line which is not connected.
Selection
•
CO line number:
KX-TD816 – 01 through 08,
KX-TD1232 – 01 through 54,
( =all CO lines)
•
Connect / No Connect
Default
All CO lines – Connect
Programming
1.
Enter 400.
Display: CO Connection
2.
Press NEXT.
Display: CO Line No?
3.
Enter a CO line number.
To enter CO line number 01, you can also press NEXT.
Display example: CO01:Connect
4.
Keep pressing SELECT until the desired selection is displayed.
5.
Press STORE.
6.
To programme another CO line, press NEXT or PREV, or SELECT and the desired CO
line number.
7.
Repeat steps 4 through 6.
8.
Press END.
Conditions
•
In case of the KX-TD1232, CO01 through CO12 are for the Master System and CO13
through CO24 are for the Slave, if available.
•
To assign all CO lines to one selection, press the key at step 3. In this case, the display
shows the contents programmed for CO01.
Summary of Contents for KX-TD1232NE
Page 2: ...2 ...
Page 8: ...8 Table of Contents ...
Page 9: ...General Instructions 9 Section 1 General Instructions ...
Page 26: ...1 5 Example of Programming 26 General Instructions ...
Page 27: ...General Programming 27 Section 2 General Programming ...
Page 96: ...2 2 System Programming 96 GeneralProgramming Feature References Charge Fee Reference ...
Page 162: ...2 5 CO Line Programming 162 GeneralProgramming Feature References Intercept Routing ...
Page 171: ...2 5 CO Line Programming General Programming 171 Feature References Display Call Information ...
Page 208: ...2 6 COS Programming 208 GeneralProgramming Toll Restriction ...
Page 245: ...2 7 Extension Programming General Programming 245 Feature References Data Line Security ...
Page 297: ...DECT Programming 297 Section 3 DECT Programming ...
Page 324: ...3 1 DECT Programming 324 DECT Programming Feature References Department Codes ...
Page 335: ...3 1 DECT Programming DECT Programming 335 Display Call Information ...
Page 339: ...Default Values 339 Section 4 Default Values ...
Page 350: ...350 Default Values 682 Radio Information Data Clear Not applicable Program Default ...
Page 351: ...Default Values 351 ...