2-12
Installation
2.9
External Pager (Paging Equipment) Connection
One external pager (user-supplied) can be connected to the system as illustrated below.
Use an EIAJ RC-6701 A plug (2-conductor, ø 3.5 mm in diameter).
• Output impedance: 600
Ω
Maximum length of the cable
ø 0.8 mm – ø 1.3 mm: Under 10 m
Speaker
Amplifier
Paging Equipment
POWER
Paging Port
PAGING
• To adjust the sound level of the pager, use the volume control on the amplifier.
• Paging port is at SELV.
• Required System Programming
Section 4.2, System Programming
[106] External Paging Access Tone
• Feature Reference
Section 3, Features
Paging
☞
!
!