2-10
Installation
2.8
Extension Connection
Extension ports 01 through 08 can be used for all kinds of telephones.
Telephone Wiring
The maximum length of the extension line cord (twisted cable) which connects the system
and the extension is as follows.
2 or 4-conductor wiring is required for each extension as listed below. There are 4 pins
possible for connection: “T” (Tip), “R” (Ring), “L” (Low) and “H” (High).
• If a telephone or answering machine with an A-A1 relay is connected to the system, set
the A-A1 relay switch on the telephone or answering machine to the OFF position.
• Extension ports are at TNV.
Telephone
Single line telephones
Proprietary telephone
(e.g., KX-T7130)
Wiring
1 pair wire (A,B)
2 pair wire (L, H, A, B)
!
!
ø 0.5 mm (26 AWG); Under 140 m
ø 0.6 mm (24 AWG); Under 229 m
ø 0.8 mm (22 AWG); Under 360 m
(Extension Loop Limit: 40
Ω
)
ø 0.5 mm (26 AWG); Under 698 m
ø 0.6 mm (24 AWG); Under 1128 m
ø 0.8 mm (22 AWG); Under 1798 m
(Extension Loop Limit: 600
Ω
including set)
ø 0.5 mm (26 AWG); Under 140 m
ø 0.6 mm (24 AWG); Under 229 m
ø 0.8 mm (22 AWG); Under 360 m
(Extension Loop Limit: 40
Ω
)
Proprietary Telephone
Single Line Telephone
DSS Console
(KX-T7040)
PSQX1708ZA-03E.QX 99.10.15 5:46 PM Page 10
Summary of Contents for KX-TA624
Page 15: ...Section 1 Basic System Construction ...
Page 17: ...Section 2 Installation ...
Page 51: ...Section 3 Features ...
Page 125: ...Section 4 System Programming ...
Page 212: ...4 88 System Programming ...
Page 213: ...Section 5 Appendix ...
Page 222: ...5 10 Appendix ...
Page 223: ...Section 6 Troubleshooting ...
Page 227: ...Section 7 Programming Tables ...
Page 275: ...Section 1 Installation ...
Page 287: ...Section 2 Operations ...
Page 306: ...10 ...
Page 409: ...Appendix Section 2 Appendix ...
Page 420: ...2 12 Appendix ...
Page 426: ...Memo ...
Page 427: ......